AcceleRAID 352 Error Messages

persists, it most likely indicates a genuine failure and needs to be corrected. To correct it, boot and run the on-board BIOS Configuration Utility, RAID EzAssist (see Chapter 3). For more information, refer to the RAID EzAssist Configuration Utility User Reference Guide or RAID EzAssist Configuration Utility Quick Configuration Guide.

With Firmware 6.x, if the BIOS displays a mismatch in the Configuration on Disk (COD) on all drives, then there will be an “install abort”-- no drives will be installed. Normally this error will not be displayed. If it is, boot and run RAID EzAssist, the on-board Mylex Disk Array Configuration Utility (see Chapter 3) to recover from the error. For more information, refer to the RAID EzAssist Configuration Utility User Reference Guide or RAID EzAssist Configuration Utility Quick Configuration Guide.

System Reboot or Power Down

Status messages may also be available from LED indicators connected to the controller. The Cache Dirty indicator is especially important when preparing to power-down the system.

The AcceleRAID 352 controller is a caching controller with 32MB, 64MB, or 128MB of cache memory, data may still be in the cache waiting to be written to the disk drives, when the system reports that a write command was completed. It is very important to make sure that all data is written to the disk before rebooting or powering down the system, or you may lose data. It is always a good idea to wait for 60 seconds or until all activity stops before resetting or rebooting the system.

Manual No. 775051

C-3