Installation Abort

If the firmware detects that during the last power cycle the system was turned off abruptly leaving some incomplete write operations, the following message appears:

Recovery from mirror race in progress

WARNING: Dead SCSI devices (Channel Target) : x:y

The following messages may also appear:

AcceleRAID 352 cannot recover from Mirror Race! Some system drives are inconsistent!

During the initialization, if the firmware fails to respond to the BIOS inquiry within two minutes, the following message displays:

AcceleRAID 352 not responding--no drives installed!

The BIOS then inquires the firmware for its version number and other information, and prints out the following message:

AcceleRAID 352 Firmware Version x.xx

One or more of the following messages will be displayed if the firmware reports the following conditions:

Warning: X system drives offline

Warning: X system drives critical

WARNING: Dead SCSI devices (Channel : Target) : x:y No system drives installed

X system drives installed

The BIOS repeats the same process for additional RAID controllers present in the system. Then it proceeds to boot, if possible, from the first system drive on the first controller.

Installation Abort

With Firmware 6.x, the installation aborted message is displayed when the BIOS finds that the configuration of the disk drives, as stored in the NVRAM and configuration on disk, is different from what it senses at boot time. When this happens, (and a brand new installation is not being attempted) the cause is often a faulty cable or drive, or a loose connection. Check all of the connectors, cables, drives, and try to boot. If the error

C-2

AcceleRAID 352 Installation Guide