661 Brea Canyon Rd., Suite 3
Walnut, CA 91789
tel: 909.598.7388, fax: 909.598.0218
© Copyright 2005 Acnodes, Inc.
All rights reserved. Product description and product specifications
are subject to change without notice. For latest product information,
please visit Acnodes’ web site at www.acnodes.com.
RMC 7189
1U Rackmount System
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5oC increment. The default
is [070]. Press "+" or "-" on your keyboard to change this value.
Temperature Rise
This item allows the user to define the temperature rise parameter of a memory module to be used
to improve memory power management. Each setting is in
0.5oC increments. The default setting is [020]. Press "+" or "-" on your keyboard to change this
value.
Air Flow
This item allows the user to set the desired speed of air flow to the DIMM mod- ules. Each incre-
ment is one mm/sec. The default is [1500]. Press "+" or "-" on your keyboard to change this value.
Altitude
This item allows the user to specify the altitude of the location where the com- puter is used. For
Tylersburg-EP platforms, system memory thermal solution is derated up to 900m. To comply with
CPU specifications, BIOS will attempt to adjust and correct DIMM velocity based on the altitude
where the system is located in order to improve DIMM thermal performance. Altitude is defined as
the number of feet above the sea level where the computer is located. The options are Sea Level or
Below, 1~300 (above-), 301~600 (above-), 601~900 (above-),
901~1200 (above-), 1201~1500 (above-), 1501~1800 (above-), 1801~2100 (above-), 2101~2400
(above-), 2401~2700 (above-), and 2701~3000 (above-) the sea level.
DIMM Pitch
Use this feature to specify the distance of physical space between each DIMM module. Each step
is in 1/1000 of an inch. The default is [400]. Press "+" or "-" on your keyboard to change this value.
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting
the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-pro-
tected I/O resource-sharing across the Intel platforms, providing the user with greater reliability,
security and availability in networking and data-sharing. The settings are Enabled and Disabled.
SR-IOV Supported
Select Enabled to enable Single Root I/O Virtualization (SR-IOV) support which works in conjunc-
tion with the Intel Virtualization Technology and allow multiple op- erating systems running simulta-
neously within a single computer via natively share PCI-Express devices in order to enhance net-
work connectivity and performance. The options are Enabled and Disabled.