Acu-Rite 1025 5-in-1 Installation Guidelines, PC Connect Overview, PC Connect USB Modes

Models: 1025

1 13
Download 13 pages 21.77 Kb
Page 7
Image 7
5-in-1 Installation Guidelines

5-in-1 Installation Guidelines

INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the ground (higher is better for wind measurement) in an open area. Secure to fence post, 2ʼx4ʼ wood, 3/4” pipe, etc. (not included)

LEVEL INSTALLATION Use the bubble level on the top of the sensor to ensure level installation for accurate wind and rain measurement.

SOLAR CELL ORIENTATION Install the sensor with the solar cell facing SOUTH. This ensures the cell receives as much sun as possible, and orients wind direction.

PC Connect Overview

PC Connect lets you access your Weather Center data in the following ways:

Data File: Display unit logs (or stores) data so that you can download it to a PC in a data file (CSV or comma-separated values file).

PC Weather Widget: View data on your PC's screen as a widget.

Web Browser or Smartphone: Monitor sensor data remotely using AcuRiteʼs free Acu-Link online software, or from a mobile device using the free Acu-Link app, available from the iPhone App Store or Android Market.

5-in-1 Sensor Installation

1.Fasten mounting base (included) to a post or pole (not included) using the 4 longer screws included in the hardware bag.

2.Insert the mounting base into the hole on the bottom of the sensor.

3.Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble

level is centered. The solar cell

NO OBSTRUCTIONS ABOVE OR AROUND

PC Connect USB Modes

To setup PC Connect, you must first select a USB mode on the display unit:

USB Mode 1: Display Logging ON

•Display unit logs (stores) up to 2 weeks of data in memory. When memory nears capacity, display unitʼs Weather Ticker displays an alert to download memory soon.

•Transfer data to your PC using PC Connect.

USB Mode 2: Display Logging OFF (DEFAULT)

 

DISPLAY UNIT...

USB

Shows Stores

Streams

Mode Data

Data

Online*

1

 

 

 

2

 

 

 

3

 

 

 

4

 

 

 

should be facing south to properly orient the wind direction vane.

3.Fasten the sensor into the mounting base using the 2 shorter screws included in the hardware bag.

The 5-in-1 sensor is now

ready to use.

(1.5 meters)

•Display unit DOES NOT log (save) any data in memory for PC transfer.

USB Mode 3: Display Logging ON/Internet Bridge Mode

•Display unit logs (stores) up to 2 weeks of data in memory. •Transfer data to your PC using PC Connect.

•Stream your data from your weather center to online sources.*

USB Mode 4: Display Logging OFF/Internet Bridge Mode

•Display unit DOES NOT log (save) any data in memory. •Stream your data from your weather center to online sources.*

*PC and internet connection must remain ON to continuously stream data from your weather center to online sources or the Acu-Link mobile app.

Clear Data Collected During Installation

When installation is complete, clear erroneous data from the display unit by pressing the “CLEAR TODAY” button, on the back of the display unit inside the battery compartment. This button will clear data recorded since 12:00am.

Basic Setup is Complete

The 5-in-1 sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. If both or one of the units appear to be functioning improperly, please refer to the troubleshooting section.

12

Set the PC Connect USB Mode

1. Press the up or down arrow buttons until “SET USB MODE?” is displayed on the Selectable Category part of the display unit.

2. Press the “PC Connect Overview” button to set the mode preference.

3. Press the up or down arrows to select the USB mode.

4. Press the “5-in-1 Sensor Installation” button to confirm your selection. PC Connect USB Mode is now set.

13

Page 7
Image 7