M4 x 8mm set screws

Insert the encoder into the spar.

Center the encoder from end to end with the spar.

Lock in place by tightening the M4 set screws.

Reading head bracket

8-32 x 5/8” SHCS (trim if necessary)

To locate the reading head bracket, attach it to the reading head.

Center the axis and mark the bracket mounting holes.

Remove the bracket, drill / tap holes for 1/4-20 (M6).

8-32 x 5/8” SHCS

(M4 x 16mm)

Do not tighten prior to adjusting leveling set screws.

Attach the bracket to the machine.

Align the reading head mounting holes with the bracket holes.

Attach head to bracket / Set leveling screws / Secure fasteners.

Alignment bracket removal

Twist 45°

Slide brackets away from reading head and cable.

Slide the brackets away from the reading head.

Remove the alignment brackets and save for future use.

Proceed to page 13, “Checking Your Installation”.

 

 

 