SENC 150 Typical Mounting (s)
9
ACU-RITE
®
1/4-20x1”BHCS
withencoderwasher
Avarietyofmountingconditionscanbeaccommodated.
•Themachinecongurationdeterminesthebracketsrequiredto
install the linear encoder.
•Threetypicalmountingconditionsareshown;ush,offset,and
backupspar(asshownpreviouslyonpage4).
•The8-32SHCSfastenerlengthsshownonthispageare
suppliedwiththeencoderhardware.
•The8-32SHCSformountingthereadingheadisastandardlow
head style fastener.
•Mountingsurfacesareoffset.
•Inst allationwithoutbackupspar.
•Uselevelingscrewsinplaceofspacersorshims.
•Mountingsurfacesareushwithin.005”.
•Thereadingheadlevelingscrewsarenotrequired.
•Flushoroffsetmountingsurfaceswithabackupspar.
•Bracketusedtoreduceheadtomountingsurfacegap.
•Usereadingheadlevelingsetscrews.
Backup spar with bracket
Offset surfaces
1/4-20x1”BHCS
andencoderwasher
8-32x3/4”SHCS
Flush surfaces
ll .005
8-32x3/4”SHCS
Space of <.18”usereading
headlevelingsetscrews.
1/4-20x1/2”BHCS
andsparwasher
8-32x5/8”SHCS
(trim if necessary)
1/4-20x1/2”BHCS
andwasher
Aspace>.18”,useaspacer
orbracket(shown);<.18”use
levelingsetscrews.
516291-21_Ve00_SENC_150.indd 11 10/22/2009 10:00:42 AM