Configuring ADSL Service
Configuring Alarms
You can configure the severity of each modem alarm, or disable alarms.
1From the ADSL Configuration Menu (page 20), type 9 to select Alarm Configuration.
2Type N to move to the next alarm type until you select the one you want to configure. The following table identifies the available alarm types.
Alarm Type | Description |
|
|
LOF | Loss of Frame |
|
|
MAR | Margin |
|
|
ES | Errored Seconds |
|
|
SES | Severely Errored Seconds |
|
|
LOS | Loss of Signal |
|
|
SELF | Self test failed |
|
|
3Press the SPACEBAR to toggle to the setting you want for the alarm, then press ENTER . The following table describes the available alarm settings. The default for each alarm is E.
Setting | Description |
|
|
E | Enables the alarm as a minor alarm. |
|
|
M | Enables the alarm as a major alarm. |
|
|
D | Disables the alarm. |
|
|
24 | Megabit Modem 310F and 320F User Manual |