WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

IMPORTANT: 380, 400, and 416 volt dryers are built 4-wire only. Customer must contact the factory to special order 3-wire systems.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

3.Electrical Connections

NOTE: A wiring diagram is included with each dryer and is affixed to the rear upper right guard panel of the dryer.

The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, and L3), GROUND, and in the case of 4-wire service, the neutral. These electrical connections are made at the wire leads located in the electric service and relay box at the rear upper left hand corner of the dryer. To gain access into this service box, the service cover must be removed.

Providing local codes permit, power connections to the dryer can be made by the use of a flexible underwriters laboratory listed cord and pigtail (wire size must conform to rating of the dryer), or the dryer can be hard wired directly to the service breaker. In ALL cases, a strain relief must be used where the wires enter the dryer’s electrical service (relay) box.

a.Gas and Steam Models ONLY

These electrical connections are made at the terminal block located in the electric service (relay) box at the rear upper left-hand corner of the dryer. To gain access into this service box, the service cover (upper back guard) must be removed.

20

American Dryer Corp.

113202 - 10

Page 24
Image 24
ADC AD-115ES installation manual American Dryer Corp 113202