L.PREOPERATIONAL INSTRUCTIONS

1.The light emitting diode (L.E.D.) display reads “READY” (no cycle in progress).

2.Press the letter on the keypad corresponding to the cycle desired (i.e., key “D”).

NOTE: “0-40” WILL REQUIRE THE “START/ENTER” KEY TO BE PRESSEDAFTER THE NUMBER IS SELECTED IN ORDER TO ACCEPT THE SELECTION AND START DRYING.

3.The dryer will then start (i.e., blower, basket [tumbler], and heat).

4.The L.E.D. display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.

NOTE: Press and hold the “UPARROW” to view the basket (tumbler) temperature at any time.

NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key, at this time the dryer will go into a cycle pause. If the “STOP/CLEAR” key is pressed again at this point, the cycle that was in progress will be cancelled and returned to the “READY” state.

NOTE: Press and hold the “DOWN ARROW” to view the basket (tumbler) RPM.

5.When the programmed drying time has expired, the Phase 7 microprocessor controller (computer) will proceed into the Cool Down Cycle.

6.Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL DOWN TEMP ___/___ MINUTES REMAINING. At the end of the heat cycle, the dryer will shut off the heat and continue the fan and basket (tumbler) until the Cool Down Time or temperature is reached.

IMPORTANT: For more detailed information regarding the microprocessor controller (computer) on your dryer, refer to the microprocessor user’s manual included with the dryer.

DUAL TIMER DRYERS

1. Turn drying timer knob for a time of 20 minutes.

2. Select “High Temp.”

3. Push “Push to Start” button.

4. To stop dryer, open the main door.

Spin and dwell (stop) times are adjustable at the reversing timer.

34

American Dryer Corp.

113202 - 10

Page 38
Image 38
ADC AD-115ES installation manual Preoperational Instructions, Dual Timer Dryers