ADCP-80-570 • Issue 2 • March 2006 • Preface

ABOUT THIS MANUAL

This manual describes the PowerWorx Circuit Breaker Panel With Reset Switch, and provides all information required to install, test, and operate this product.

STANDARD CERTIFICATION

The panel conforms to the applicable requirements of the following: UL/CSA/EN 60950, FCC Part 15, CISPR 22, and CISPR 24.

ADMONISHMENTS

Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments — in the form of Dangers, Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below), and are listed in descending order of severity of injury or damage and likelihood of occurrence.

Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided.

Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided.

Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided.

GENERAL SAFETY PRECAUTIONS

-

Warning: The circuit breaker panel uses electrical voltage and current levels that may be considered an energy hazard. Only qualified personnel should be allowed to install, operate, maintain, or otherwise come into contact with this equipment when energized. Only insulated tools should be used on energized elements of the panel.

Warning: Disconnect or turn off the power before connecting the input or output wires on the circuit breaker panel. This may require turning off the system office battery input at the battery distribution fuse bay or turning off the circuit breakers at the panel.

Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm.

Page v

© 2006, ADC Telecommunications, Inc.

Page 5
Image 5
ADC Circuit Breaker Panel With Reset Switch user manual About this Manual, Standard Certification, Admonishments

Circuit Breaker Panel With Reset Switch specifications

An ADC Circuit Breaker Panel with Reset Switch is an essential component in modern electrical systems, designed to enhance safety and efficiency in power distribution. This panel serves as a protective mechanism, safeguarding electrical circuits from overloads and short circuits, while the reset switch provides a user-friendly means of restoring functionality without the need for complete disconnection.

One of the primary features of the ADC Circuit Breaker Panel is its advanced circuit protection technology. Utilizing either thermal or magnetic mechanisms, these breakers can detect abnormalities in current flow and automatically interrupt the circuit. Thermal breakers respond to excessive heat generated by an overload, while magnetic breakers react quickly to short circuits, ensuring minimal damage to both the electrical system and connected appliances.

Another important characteristic of this panel is its modular design. The customizable layout allows for the integration of various circuit breakers based on specific requirements, accommodating different circuit voltages and capacities. This adaptability makes the ADC Circuit Breaker Panel suitable for a wide range of applications, from residential homes to commercial buildings and industrial settings.

Energy efficiency is a key concern in modern electrical design, and the ADC panel plays a significant role in this aspect. With features like smart monitoring systems, users can keep track of power consumption, helping to identify inefficiencies and reduce energy waste. This promotes sustainable practices and can lead to significant cost savings over time.

Incorporating modern technologies, these panels often come equipped with digital displays and connectivity options. This enables real-time monitoring and alerts for any irregularities, enhancing overall system reliability. Some models even support remote access, allowing users to manage and monitor their electrical systems from anywhere, further increasing convenience and safety.

Moreover, safety is paramount in the design of ADC Circuit Breaker Panels. The inclusion of a reset switch means that instead of replacing blown fuses or constantly resetting breakers manually, users can simply press the switch to restore power. This feature not only saves time but also reduces the risk of accidental electrical mishaps.

In summary, the ADC Circuit Breaker Panel with Reset Switch blends advanced technology, adaptability, and enhanced safety features into a compact design. With its capacity for efficient energy management and user-friendly operation, it stands out as a crucial element in the evolution of electrical distribution and protection systems.