C.Dryer will not start, but computer display indicators are on...

1.Failed contactors.

2.Failed arc suppressor (A.S.) board.

3.Failed microprocessor controller (computer).

4.Failed motors.

D.Drive motor runs, burner is on, but basket will not turn...

1.Broken, damaged or loose V-belt.

2.Belts contaminated (oil, grease, etc.).

3.Loose or broken pulley.

E.Dryer operates but is taking too long to dry...

1.Improperly programmed microprocessor controller (computer).

2.An inadequate exhaust duct work system.

3.Restriction in exhaust system.

4.Insufficient make-up air.

5.Poor housekeeping.

Dirty or clogged lint screen.

6.Washing machine extractors are not performing properly.

7.An exceptionally cold/humid or low barometric pressure atmosphere.

8.The supply gas may have a low heating valve...check with local gas supplier.

9.Failed temperature sensor (temperature calibration is incorrect).

10.Failed microprocessor controller (computer).

F.Thermal overload for drive motor is tripping...

1.Either an exceptionally low or high voltage supply.

2.Motor bearing failure.

3.Motor vents are blocked with lint.

4.Failed motor.

5.Failed overload.