6.Out of balance impellor (fan).

7.Insufficient make-up air.

G.Overload for impellor (fan) motor is tripping...

1.Either an exceptionally low or high voltage supply.

2.Motor bearing failure.

3.Motor vents are blocked with lint.

4.Failed motor.

5.Failed overload.

6.Insufficient make-up air.

H.Burner hi-limit safety thermostat is tripping...

1.Insufficient exhaust duct work, size, or restriction in exhaust system.

2.Insufficient make-up air.

3.Lint screen needs cleaning.

4.Damaged impellor.

I.L.E.D. (light emitting diode) display reads “Temp Sensor Failure Check Temp Sensor Fuse”...

1.Check 1/8-amp fuse on microprocessor (computer).

2.Faulty microprocessor temperature sensor probe.

3.Open circuit in either one of two (2) wires leading from the sensor probe to the computer...

a.Connection at sensor bracket assembly connector.

b.Connection at computer harness connector.

4.Faulty microprocessor controller (computer).

J.Dryer does not start...display reads “main door” or “lint door” with an audio indication...

1.Main door is open.

2.Lint drawer is open.

3.Faulty main door or lint door switch.

4.Open circuit in either main door or lint drawer switch harnesses.

5.Faulty 24 VAC transformer.

45