Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

 

 

 

 

 

 

 

 

 

 

 

 

BZS –

Error buzzer function

 

 

 

 

 

 

 

 

 

 

 

 

EZ

Automatic rebuilding to spare drive (one of the drives on the raid is set as a

 

 

spare). If EZ is ENABLED anda drive failure occurs, the spare will

 

 

automatically act as a drive replacement and rebuilding will automatically

 

 

start.

 

 

OFF

 

OFF

 

OFF

 

OFF

 

OFF

M2

RAID mode 2

 

 

 

 

 

 

M1

RAID mode 1

SW1

 

1

 

2

 

3

 

4

 

5

 

 

M0

RAID mode 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BZS EZ

 

M2 M1 M0

 

1.Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

2.Auto-rebuilding to spare drive is DISABLED (EZ)

3.Individual drive mode is ENABLED (M0~M2)

Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.

LED Pin Header

J3J1

 

 

 

P5 P0 P1 P2 P3 P4

 

P5 P0 P1 P2 P3 P4

Error LED

 

Activity LED

J1 – Drive Activity LED

P5 – Activity LED for eSATA host port lights up when it is connected to a SATA controller card.

P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity.

J3 – Error LED

P5 – error LED for eSATA host port

P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5

3

Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program:

1.For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume.

It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager.

2.Modify the RAID mode on the 5-port HPM-XA using DIP switch

Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below.

Note: Steps A to D need to be performed each time the raid mode is modified.

a.Set the DIP switch to factory default setting.

OFF

OFF

OFF

OFF

OFF

SW1

1 2 3 4 5

 

BZS EZ M2 M1 M0

b.Press the RAID setting button with a ball point pen.

c.While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the

RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset.

d.Power off the system power.

4

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)

Phone: 408-453-6212

Email: www.addonics.com/support/query/

Page 3
Image 3
Addonics Technologies RT3DAHEU3 manual Default factory DIP Switch setting, LED Pin Header