Default factory DIP Switch setting:
SW1 – RAID Setting DIP Switch |
|
|
|
|
|
|
|
|
|
|
|
| |||
BZS – | Error buzzer function |
|
|
|
|
|
|
|
|
|
|
|
| ||
EZ | – | Automatic rebuilding to spare drive (one of the drives on the raid is set as a | |||||||||||||
|
| spare). If EZ is ENABLED anda drive failure occurs, the spare will | |||||||||||||
|
| automatically act as a drive replacement and rebuilding will automatically | |||||||||||||
|
| start. |
|
| OFF |
| OFF |
| OFF |
| OFF |
| OFF | ||
M2 | – | RAID mode 2 |
|
|
|
|
|
| |||||||
M1 | – | RAID mode 1 | SW1 |
| 1 |
| 2 |
| 3 |
| 4 |
| 5 |
|
|
M0 | – | RAID mode 0 |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BZS EZ |
| M2 M1 M0 |
|
1.Error buzzer function is ENABLED (BZS) when dip switch is in OFF position
2.
3.Individual drive mode is ENABLED (M0~M2)
Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.
LED Pin Header
J3J1
|
|
|
P5 P0 P1 P2 P3 P4 |
| P5 P0 P1 P2 P3 P4 |
Error LED |
| Activity LED |
J1 – Drive Activity LED
P5 – Activity LED for eSATA host port lights up when it is connected to a SATA controller card.
P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity.
J3 – Error LED
P5 – error LED for eSATA host port
P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5
3
Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program:
1.For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume.
It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager.
2.Modify the RAID mode on the
Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below.
Note: Steps A to D need to be performed each time the raid mode is modified.
a.Set the DIP switch to factory default setting.
OFF | OFF | OFF | OFF | OFF |
SW1 | 1 2 3 4 5 |
| BZS EZ M2 M1 M0 |
b.Press the RAID setting button with a ball point pen.
c.While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the
RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset.
d.Power off the system power.
4
www.addonics.com
Technical Support | Phone: | Email: www.addonics.com/support/query/ |