Dell
Table 8. RAID Level Migration
| Source RAID |
|
| Target RAID |
|
| # of Physical |
|
| # of Physical |
|
| Capacity |
| Description |
| Level |
|
| Level |
|
| Drives |
|
| Drives (End) |
|
| Expansion |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| (Beginning) |
|
|
|
|
| Possible |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 0 |
|
| RAID 1 |
| 1 |
| 2 |
|
| No |
| Converting non- | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| redundant virtual disk |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| into a mirrored virtual |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| disk by adding one drive. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 0 |
|
| RAID 5 |
|
| 1 or more |
|
| 3 or more |
|
| Yes |
| At least one drive needs |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| to be added for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| distributed parity data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 0 |
|
| RAID 6 |
|
| 1 or more |
|
| 4 or more |
|
| Yes |
| At least two drives need |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| to be added for dual |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| distributed parity data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| RAID 1 |
|
| RAID 0 |
| 2 |
|
| 2 or more |
|
| Yes |
| Removes redundancy | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| while increasing |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| capacity. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| RAID 1 |
|
| RAID 5 |
| 2 |
|
| 3 or more |
|
| Yes |
| Maintains redundancy | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| while doubling capacity. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| RAID 1 |
|
| RAID 6 |
| 2 |
|
| 4 or more |
|
| Yes |
| Two drives are required | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| to be added for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| distributed parity data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 5 |
|
| RAID 0 |
|
| 3 or more |
|
| 3 or more |
|
| Yes |
| Converting to a non- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| redundant virtual disk |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| and reclaiming disk space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| used for distributed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| parity data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 5 |
|
| RAID 6 |
|
| 3 or more |
|
| 4 or more |
|
| Yes |
| At least one drive needs |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| to be added for dual |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| distributed parity data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 6 |
|
| RAID 0 |
|
| 4 or more |
|
| 4 or more |
|
| Yes |
| Converting to a non- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| redundant virtual disk |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| and reclaiming disk space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| used for distributed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| parity data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RAID 6 |
|
| RAID 5 |
|
| 4 or more |
|
| 4 or more |
|
| Yes |
| Removing one set of |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| parity data and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| reclaiming disk space |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| used for it. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4.5Fault-Tolerance Features
Below is a list of features that provide fault tolerance to prevent data loss:
∙
∙Support for SMART
∙Redundant path support (for PERC H800 only)
∙Physical disk failure detection
DELL PERC H700 and H800 Technical Guide | 16 |