Dell

Table 8. RAID Level Migration

 

Source RAID

 

 

Target RAID

 

 

# of Physical

 

 

# of Physical

 

 

Capacity

 

Description

 

Level

 

 

Level

 

 

Drives

 

 

Drives (End)

 

 

Expansion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Beginning)

 

 

 

 

 

Possible

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 0

 

 

RAID 1

 

1

 

2

 

 

No

 

Converting non-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

redundant virtual disk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

into a mirrored virtual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disk by adding one drive.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 0

 

 

RAID 5

 

 

1 or more

 

 

3 or more

 

 

Yes

 

At least one drive needs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to be added for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distributed parity data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 0

 

 

RAID 6

 

 

1 or more

 

 

4 or more

 

 

Yes

 

At least two drives need

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to be added for dual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distributed parity data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 1

 

 

RAID 0

 

2

 

 

2 or more

 

 

Yes

 

Removes redundancy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

while increasing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

capacity.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 1

 

 

RAID 5

 

2

 

 

3 or more

 

 

Yes

 

Maintains redundancy

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

while doubling capacity.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 1

 

 

RAID 6

 

2

 

 

4 or more

 

 

Yes

 

Two drives are required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to be added for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distributed parity data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 5

 

 

RAID 0

 

 

3 or more

 

 

3 or more

 

 

Yes

 

Converting to a non-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

redundant virtual disk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and reclaiming disk space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

used for distributed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parity data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 5

 

 

RAID 6

 

 

3 or more

 

 

4 or more

 

 

Yes

 

At least one drive needs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to be added for dual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distributed parity data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 6

 

 

RAID 0

 

 

4 or more

 

 

4 or more

 

 

Yes

 

Converting to a non-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

redundant virtual disk

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and reclaiming disk space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

used for distributed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parity data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAID 6

 

 

RAID 5

 

 

4 or more

 

 

4 or more

 

 

Yes

 

Removing one set of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parity data and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reclaiming disk space

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

used for it.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.5Fault-Tolerance Features

Below is a list of features that provide fault tolerance to prevent data loss:

Non-volatile cache: extends data retention from hours to years

Support for SMART

Redundant path support (for PERC H800 only)

Physical disk failure detection

DELL PERC H700 and H800 Technical Guide

16

Page 16
Image 16
Dell H800, H700 manual Fault-Tolerance Features, RAID Level Migration