61200214L1-1 IQ Probe User Manual 59
Chapter 8. Configuring Dial Backup Options
In this chapter, the terminal selections are listed first followed by the
Front Panel selections in parenthesis (if the names differ).
Auto DBU
The AUTOMATIC DBU option specifies whether the unit
automatically enters dial backup mode or waits for manual
setup. The factory default setting is DISABLE.
DBU Options
Beeper Option (BEEP OPTION)
If enabled, the IQ Probe issues an intermittent beep while in dial
backup.
Password Opt
When enabled, the passwords entered in the DBU PASSWORD
fields of both the near and far end IQ devices are required to
match before a dial backup connection can be made. The setting
in this field must also be identical in both units (i.e., they both
must be set to either ENABLED or DISABLED).
DBU Password
Enter the authentication string used for making a dial backup
connection. The near and far end IQ devices must have identical
DBU passwords. If using front panel entry, see the section
Entering Letters Using the Front Panel in the chapter System
Configuration for more information.
Daily Lockout
Enable this field to disable dial backup during a certain time
period each day. The time period is specified in the LOCKOUT
START and LOCKOUT END fields.
Lockout Start
Enter the hour that the daily lockout begins and dial backup is
disabled (0 to 23). This setting only applies if the DAILY LOCK-
OUT parameter is enabled.