Chapter 11. Testing

View Test

Displays the Test Statistics menu shown in Figure 11-4. Descrip- tions of each field in the Test Statistics menu follow:

PVC Active/Inactive/Undefined

Displays current state of the selected PVC as determined by the switch (only available in the terminal menu).

Active: The PVC is currently operational.

Inactive: There is currently a physical or frame relay layer problem at the remote end of the PVC, or a problem exists inside the frame relay cloud for the selected PVC.

Undefined: The PVC is undefined for the switch.

Test Active/No Test Active

Displays current testing state of the IQ Probe (only available in the terminal menu).

Frames Rx

Number of frames received on the selected PVC during the current loopback test.

Frames Tx

Number of frames transmitted across the selected PVC during the current loopback test.

Lost Frames

Number of frames lost in the receiving direction (traveling from the remote IQ device to the local IQ Probe).

Remote Lost Frames

Number of frames lost in the transmitting direction (traveling from the local IQ Probe to the remote IQ device).

Minimum Loop Response Time (MIN RESP TIME)

Minimum round-trip time (in seconds) for the current test.

Maximum Loop Response Time (MAX RESP TIME)

Maximum round-trip time (in seconds) for the current test.