Table 1. Preprovisioning

In lieu of option switches, the TROCU DP Preferred Option has been preprovisioned with feature settings as indicated in Table 1.

Table 1. Preprovisioning

Feature

Setting

 

 

Latching Loopback

ON

 

 

Zero Code Suppression

ON (Unless 56 kbps, SC, and

64 kbps = OFF)

 

 

 

Error Correction

OFF

 

 

3. INSTALLATION

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

The TROCU DP plugs directly into a WECO or equivalent D4 channel bank or the ADTRAN ACT 1900/2300 channel bank. No special wiring is required. The two-wire loop uses the T/R (Tip and Ring) pair, pins 24 and 51 of the D4 backplane.

Span-powering is accomplished using -130 V, measured from Tip to Ring. Voltage measured from Tip to GND should indicate approximately -130 V; voltage from Ring to GND should indicate approximately 0.0 V.

When inserted into a powered up backplane the TROCU DP and TRDDS-R will synchronize within 30 to 90 seconds. When synchronized, the SYNC LOSS indicator LED will turn Off. If synchronization cannot be achieved, check the T/R pair for an open circuit or short circuit condition, or load coils (see LED Indicators).

4. TESTING

Testing for the TROCU DP is accomplished using the same test procedures for four-wire OCU and OCU DP units. Table 2 describes cable loss for the TRDDS Nyquist frequency of 13.3 kHz.

The TROCU DP is equipped with logic level bantam test access jacks that permit testing in both directions using a portable test set. Latching and alternating OCU and CSU loopback sequences are supported. Alternating loopbacks do not operate when the 64 kbps data rate is selected. Choose NEAR to test toward the customer loop; choose FAR to test toward the T-carrier.

In the FAR direction, an OCU loopback sequence will loop the unit directly across the T-carrier system. In the NEAR direction, an OCU loopback sequence will loop the unit directly connected to the portable test set.

NOTE

If 64 kbps is selected, the unit will only respond to latching loopback sequences. Alternating sequences are not valid at this rate.

Table 2. Cable Type Loss Data @ 13.3 kHz

 

 

Plastic Cable

dB Loss/kft

 

Paper Cable

dB Loss/kft

 

 

 

 

 

 

 

 

 

 

19

Gauge PIC (0F)

0.5302

19

Gauge PULP (0F)

0.5616

 

 

19

Gauge PIC (70F)

0.6083

19

Gauge PULP (70F)

0.6415

 

 

19

Gauge PIC (120F)

0.6610

19

Gauge PULP (120F)

0.6955

 

 

 

 

 

 

 

 

 

 

22

Gauge PIC (0F)

0.912

22

Gauge PULP (0F)

0.9454

 

 

22

Gauge PIC (70F)

1.0258

22

Gauge PULP (70F)

1.0606

 

 

22

Gauge PIC (120F)

1.1015

22

Gauge PULP (120F)

1.1370

 

 

 

 

 

 

 

 

 

 

24

Gauge PIC (0F)

1.2571

24

Gauge PULP (0F)

1.2900

 

 

24

Gauge PIC (70F)

1.3982

24

Gauge PULP (70F)

1.4324

 

 

24

Gauge PIC (120F)

1.4917

24

Gauge PULP (120F)

1.5268

 

 

 

 

 

 

 

 

 

 

26

Gauge PIC (0F)

1.6823

26

Gauge PULP (0F)

1.6751

 

 

26

Gauge PIC (70F)

1.8568

26

Gauge PULP (70F)

1.8469

 

 

26

Gauge PIC (120F)

1.9718

26

Gauge PULP (120F)

1.9608

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 