9-10 61200290L1-1G
Section 9, Transaction Language 1 (TL1) MX2800 M13 Multiplexer User Manual
RTRV-COND-{EQPT|rr|ALL}:<tid>::<ctag>;
Description Retrieves the requested alarms and conditions
MOD2 Specifies what entity type to query:
EQPT General Equipment Unit
rr Facility or Circuit (i.e. T1, VT1, STS1)
ALL All entity types
TID Target ID
AID* Identifies the component to which the desired alarm pertains. Identifiers are integers
and are dependent on the entity specified in “MOD2” as follows:
for EQPT:
401 Generic
402 Control Card A
403 Control Card B
404 Power Supply A
405 Power Supply B
ALL all EQPT identifiers (default selection)
for T1:
101 DS1#1
102 DS1#2
.
128 DS1#28
ALL all DS1 circuits (default selection)
for T2:
201 DS2#1
202 DS2#2
.
207 DS2#7
ALL all DS2 circuits (default selection)
for T3:
301 DS3#1
302 DS3 (Control Card A)
303 DS3 (Control Card B)
ALL all DS3 circuits (default selection)
for ALL:
x specific identifier (e.g. 1, 28, etc.)
ALL all identifiers (default selection)
CTAG* Transaction Number (integer)
Table 9-2. TL1 Commands (Continued)