9-20 61200290L1-1G
Section 9, Transaction Language 1 (TL1) MX2800 M13 Multiplexer User Manual
Data Dictionaries
The data dictionaries that follow are to be used while performing TL1 editing or retrieve commands. Each
data dictionary contains four columns. The columns are as follows:
• Keyword gives the values to be placed in the <keyword> portion of the edit command.
• Type describes the type of <value> that is required to be entered in the edit command.
ENUM requires a text and/or number string to be entered as the <value>.
Y/N requires a Y or N representing yes or no to be entered as the <value>.
INT requires that an integer be entered as the <value>.
• Domain describes va lid entries that may be entered into the <value> portion of the edit command.
• Description explai ns each of the edit or retrieve commands.
Tabl e 9- 6 contains entries that are used to edit or retrieve options for the DS3 portion of the MX2800.
When performing TL1 edit commands from this table, the value of rr should be T3, and the <aid> value
should be one of the following:
• 300 for all DS3 Circuits
• 301 for DS3 #1
• 302 for DS3 Control Card A
• 303 for DS3 Control Card B
Table 9-6. TL1 Editing Data Dictionary for DS3
Keyword Type Domain Description
ACTIVECONTROLLER ENUM One of the following:
•A
•B
Selects which controller card is active
controller card A is active
controller card B is active
CARDSWRLY Y/N Y or [N] Identifies status of System Protection Switch
alarm relay
Yes (Y) - enables alarm
No (N) - disables alarm
DIAGDS3 ENUM One of the following:
•DATAMODE
• LINELPBK
•DIGLPBK
• METLPBK
•REMLPBK
• ALLT1
Enables the selected DS3 loopback
Refer to Data Mode on page6-2
Refer to Line Loopback on page6-7
Refer to Digital Loopback on page6-7
Refer to Metallic Loopback on page6-8
Refer to Remote Loopback on page6-8
Refer to Remote All T1/E1 on page6-8
DS3AISRLY Y/N Y or [N] Identifies status of DS3 AIS alarm relay
Yes (Y) - enables alarm
No (N) - disables alarm