ADTRAN T200 IDSL Event First Last Current, DDS Sync Loss, Clear, DDS Loop Open, OCU-R Power, Esc

Models: T200 IDSL

1 18
Download 18 pages 14.24 Kb
Page 14
Image 14

The Event Log, shown in Figure 19, loads and time- stamps IDSL circuit performance anomalies and threshold violations. This screen is a very useful aid in troubleshooting a chronic circuit. It monitors DDS sync loss, DDS open loop, IDSL OCU-R margin, IDSL sync loss, and power-up events. IDSL loop signal-to-noise margin is calculated on a numerical scale from 0-20 with 0 approximately equal to a BER of 1 x 10 -6and 20 equal to virtually a 0 BER.

The Set Circuit ID screen, Figure 20, sets the circuit identification.

CIRCUIT ID:IDSL Test Unit

 

 

07/25/00 02:38:13

 

 

EVENT LOG

 

 

 

EVENT

FIRST

LAST

 

CURRENT

COUNT

DDS SYNC LOSS

07/24/00 11:10:04

07/24/00

20:45:03

CLEAR

255

DDS LOOP OPEN

07/24/00 11:10:04

07/24/00

20:45:03

CLEAR

020

OCU-R MARGIN

-------- --------

--------

--------

CLEAR

---

DSL SYNC LOSS

07/24/00 11:10:04

07/24/00

20:45:03

CLEAR

021

OCU-R POWER

07/24/00 11:10:01

07/25/00

02:00:00

CLEAR

017

LAST LOG RESET

01/03/98 03:33:20

 

 

 

 

 

<ENTER>

To CLEAR the

Event Log

 

 

 

<ESC>

To exit without destroying data

 

 

 

 

 

 

Figure 19. Event Log Screen

 

 

 

 

 

 

CIRCUIT ID:IDSL Test Unit

 

 

07/25/00 02:38:36

 

Set Circuit ID

 

 

 

New ID =

Figure 20. Set Circuit ID Screen

14