Symptom
The food is too warm.
Interior lighting does not work.
Heavy build up of frost, possibly also on the door seal.
Possible Cause
Temperature is not properly adjusted. Door was open for an extended period.
A large quantity of warm food was placed in the appliance within the last 24 hours.
The appliance is near a heat source.
Light bulb is defective.
Door seal is not air tight (possibly after reversing the door).
Remedy
Please look in the “Initial Start Up” section.
Open the door only as long as necessary.
Turn the temperature reg- ulation to a colder setting temporarily.
Please look in the “Installation location” section.
Please look in the “Changing the Light Bulb” sections.
Carefully warm the leaking sections of the door seal with a hair dryer (on a cool setting). At the same time shape the warmed door seal by hand such that it sits correctly.
|
| Appliance is not level. |
| Readjust the feet. |
Unusual noises. |
|
|
|
|
|
|
|
| |
| The appliance is touching |
| Move the appliance | |
|
|
| ||
|
| the wall or other objects. |
| slightly. |
|
|
|
|
|
The compressor does not |
|
|
|
|
start immediately after |
| This normal, no error has |
| The compressor starts after |
changing the temperature |
| occurred. |
| a period of time. |
setting. |
|
|
|
|
|
|
|
|
|
Water on the floor or on |
| Water drain hole is | See the “Cleaning and | |
storage shelves. |
| blocked. |
| Care” section. |
|
|
|
|
|
21