Operating instructions

Malfunction

Possible Cause

Remedy

 

The height adjustable threa-

Adjust threaded feet as per

 

ded feet are not correctly

 

the installation instructions.

 

adjusted.

 

 

 

There is only very little

 

 

washing in the drum (e.g.

Function is not impaired.

Washing machine

only a towelling dressing

 

vibrates during opera-

gown).

 

tion or is unstable.

Water cannot be completely

Check the drain hose and if

 

 

pumped out because the

necessary remove any kink or

 

drain hose is kinked

clean the circulation pump

 

or

and remove any foreign

 

the circulation pump is bloc-

bodies from the pump hou-

 

ked.

sing.

Excessive foaming

Probably too much detergent

Dose detergent exactly in

accordance with the manu-

during the main wash.

was used

facturer’s instructions.

 

 

 

Threaded fitting on the

Tighten the water inlet hose

 

water inlet hose is leaking.

 

 

 

 

 

 

Drain hose is leaking.

Check drain hose and if

Water runs out from

necessary replace.

 

 

 

under the washing

Circulation pump cover is

Close cover properly.

machine.

not closed properly.

 

 

 

 

 

 

Washing is trapped in the

Stop program, remove

 

washing from the door, start

 

door.

 

a new program.

 

 

Softener is not washed

Suction cap in the compart-

Clean detergent drawer,

in, w compartment

ment for conditioner is not

place suction cap firmly in

for conditioner is full

correctly positioned or is

position.

with water.

blocked.

 

 

 

 

Appliance does not

o (RINSE HOLD) selected.

Deselect o (RINSE HOLD).

 

Pump out the water and set

spin, water in the

 

drum.

Soaking program is finished.

the main wash cycle as

 

 

desired.

 

 

 

28