Water inflow

A 1.50 m long pressure hose is supplied with the appliance.

If a longer water inlet hose is required, only original hoses are to be used. The Customer Care Department stocks hose kits of different lengths.

3 Sealing rings are either inserted in the nuts of the threaded hose fitting or are included as spare parts . Do not use any other type of sealing rings.

Important! All threaded hose fit- tings must only be tightened by hand.

1.Connect the hose with the right-an-

gle connector to the machine.

Important! Do not position the inlet hose vertically downwards. Position it to the right or the left as shown in the illustration.

2. Connect the hose with the straight connector to a water tap with an R ¾ (inch) screw thread.

3. To tighten or loosen the threaded hose fitting, only the metal nuts must be turned. When doing this, keep a firm hold on the housing of the safety valve with one hand, so that it does not turn at the same time.

Important! To tighten or loosen the threaded hose fitting, never turn the housing of the safety valve, as oth- erwise the inner hose will be dam- aged.

4.Open the water tap slowly and check all connections for water tight- ness.