AEG LAVAMAT 64850L, L64850L user manual Emergency emptying out, Turn on the water tap

Models: LAVAMAT 64850L L64850L

1 36
Download 36 pages 2.66 Kb
Page 23
Image 23

22Care and cleaning

1. Turn off the water tap.

2. Unscrew the hose from the tap.

3. Clean the filter in the hose with a stiff brush.

4. Screw the hose back onto the tap. Make sure the connection is tight.

5. Unscrew the hose from the machine. Keep a rug nearby because some water may flow.

6. Clean the filter in the valve with a stiff brush or with the piece of cloth.

7. Screw the hose back to the machine and make sure the connection is tight.

8. Turn on the water tap.

Emergency emptying out

If the water is not discharged, proceed as follows to empty out the machine:

1.pull out the plug from the power socket;

2.close the water tap;

3.if necessary, wait until the water has cooled down;

4.open the pump door;

5.place a bowl on the floor and place the end of the emergency emptying hose into the bowl. Remove its cap. The water should drain by gravity into the bowl. When the bowl

Page 23
Image 23