Troubleshooting

Troubleshooting

Problem

Possible Cause

Correction

Odor in cabinet

• Unit interior needs cleaned.

• Clean inside of unit. See “Care and Cleaning” pg. 7.

 

 

 

 

 

 

 

 

 

Noisy operation

 

Unit not level.

• Adjust leveling legs. See leveling leg instructions.

 

 

 

 

 

 

 

 

 

 

 

 

Unit vibrates

 

Unit not level.

• Adjust leveling legs. See leveling leg instructions.

 

 

 

 

 

 

 

 

 

 

 

Weak floor.

• Rebuild floor or move to a different location.

 

 

 

 

 

 

 

 

 

 

Interior light not working

 

LED light burned out.

Replace LED light.

 

 

 

 

 

 

 

 

 

 

• No power at outlet.

• Test outlet with lamp.

 

 

 

 

 

 

 

 

 

Appliance will not run.

 

Control Panel turned “OFF”.

• Turn unit on with on/off pad on Control Panel.

 

 

 

 

 

 

 

 

 

 

• Line Cord not plugged into power source.

• Plug unit into power source.

 

 

 

 

 

 

 

 

 

 

 

 

House fuse blown.

Reset house fuse.

 

 

Appliance runs too long.

 

Prolonged door openings.

• Reduce number and/or duration of door openings.

 

 

 

 

• Control Panel set too cold.

• Raise temperature of unit via Control Panel.

 

 

 

 

 

 

 

 

 

 

 

Condenser needs cleaning.

• Clean condenser. See “Care of Unit” pg 7.

 

 

Moisture collects inside of unit.

 

Too many door openings.

• Reduce number and/or duration of door openings.

 

 

 

 

 

 

 

 

 

 

 

Prolonged door openings.

• Reduce number and/or duration of door openings.

 

 

 

 

 

 

 

 

 

 

• Hot, humid weather increases

• As humidity decreases, moisture will disappear.

 

 

 

 

 

condensation.

• Move unit to cooler location.

 

 

 

 

 

 

 

 

 

Moisture collects on outside surface

 

Hot, humid weather increases

• As humidity decreases, moisture will disappear.

 

 

of the unit.

 

 

condensation.

• Move unit to cooler location.

 

 

 

 

Control improperly set.

• Reset to slightly warmer temperature.

 

 

Interior too hot/too cold

 

Control improperly set.

• Reset control to desired temperature.

 

 

 

 

Faulty thermometer.

• Recheck with second thermometer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostic LED

In the back in the grille there is a diagnostic/status LED. This led is used to help diagnosis any problems with the unit and to tell its status.

LED Status

Code/Problem

Not on

Unit does not have power

Continuously on

Unit is "ON" and operating correctly

1 Blink and pause

For shorted or open thermistor

2 Blink and pause

Disconnected Display Board

 

 

3 Blink and pause

Compressor is locked out

 

 