FITTING AND PRODUCT DIMENSIONS
6
Fig. 1 DESN 512636
Any side wall above the cooker on either side shall be not less than 3” (75mm) horizontally from
the cooker (Fig. 1).
Combustible surfaces over the top of the cooker must not be closer than 28” (711mm) and must
not exceed 13” (400mm) in depth.
0” clearance to the back of the stove may be obtained when installing the appliance against a
non-combustible wall or if the wall behind the stove is deemed combustible, then the minimum
spacing from the back of the stove to nearest combustible wall is 6”.
A minimum clearance of 39 1/2” (1000mm) must be available at the front of the cooker to enable
it to be serviced.
The cooker must stand on a firm and level surface, we recommend that any soft material such
as linoleum is removed.
The vent slots in the back of the top plate must not be obstructed.