INSTALLATION

CAUTION: THIS INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.I/NFPA 54 AND NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (IN CANADA CAN/CGA-B149) AND ONLY USED IN A WELL VENTILATED SPACE, READ THESE INSTRUCTIONS BEFORE INSTALLING OR USING THIS APPLIANCE.

PRIOR TO INSTALLATION, ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS (NATURE OF GAS AND GAS PRESSURE) AND THE ADJUSTMENTS OF THE APPLIANCE ARE COMPATIBLE.

THE GAS ADJUSTMENT CONDITIONS FOR THIS APPLIANCE ARE STATED ON THE DATA PLATE WHICH IS SITUATED IN THE CENTRE VENT SLOT NEAR THE BASE OF THE FRONT PLATE.

This appliance is not connected to a combustion products evacuation device. it shall be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.

It should be in accordance with any relevant requirements of the Gas Region and Local Authority.

The appliance must be disconnected from the gas supply piping system during any pressure testing of that system test pressure in excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psi (3.5 kPa).

On completion, test the gas installation for soundness and purge. Leak testing of the appliance shall be conducted according to the manufacturer’s instructions.

NOTE: Use soapy water solution on new gas connections to ensure there are no gas leaks.

WARNING: ELECTRIC SHOCK HAZARD

It is the customers responsibility to contact a qualified electrical installer to make sure the electrical installation is adequate and in conformance with National Electrical Code ANSI/FPA 70-latest edition, and all local codes and ordinances.

Take special care when cutting holes in walls or floor. Electrical wires may be behind the wall or floor covering and could cause an electrical shock if you touch them.

Locate any electrical circuits that could be affected by the installation of this product and disconnect power circuit.

Electrical ground is required on this appliance.

Do not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.

Do not use an extension cord with this appliance.

Check with a qualified electrician if you are not sure the appliance is properly grounded.

Failure to follow these instructions could result in death or serious injury.

5

Page 5
Image 5
Aga Ranges dc6 owner manual Installation

dc6 specifications

The Aga Ranges DC6 stands as a pinnacle of craftsmanship and culinary engineering, offering an unparalleled cooking experience that combines traditional aesthetics with modern technology. Renowned for its timeless design and exceptional performance, the DC6 is a versatile addition to any kitchen, appealing to both professional chefs and home cooks alike.

One of the standout features of the Aga DC6 is its unique cooking method, which employs cast-iron heat retention technology. This enables the range to maintain a consistent and even temperature, allowing users to cook multiple dishes simultaneously without flavor transfer. The solidly built cast-iron construction holds heat for extended periods, ensuring that meals are cooked to perfection without the need for constant adjustment of flame or temperature.

The DC6 offers six distinct cooking zones, including multiple ovens and hotplates, each operating at a different temperature. This setup allows for a wide range of cooking techniques, including baking, roasting, simmering, and frying, all at the same time. The ovens are designed for specific tasks, such as the roasting oven that operates at a higher temperature for succulent meats, and the simmering oven that provides gentle heat for slow-cooked dishes. This versatility makes the DC6 an ideal choice for those who appreciate cooking variety.

Aga also emphasizes energy efficiency with the DC6. The range is engineered to minimize energy consumption while providing outstanding performance. Its innovative design focuses on heat retention, enabling users to cook for hours with minimal energy input. The DC6 is available in both gas and electric options, allowing customers to select the power source that best suits their cooking style and kitchen setup.

In addition to its technical features, the Aga DC6 is available in a range of beautiful colors, allowing homeowners to personalize their kitchen spaces. This customization stands out as a key characteristic, making the cooker not just a functional appliance, but a statement piece that enhances the overall aesthetic of the kitchen.

With its combination of traditional charm and modern functionalities, the Aga Ranges DC6 represents the best in high-end cooking technology. Its robust construction, diverse cooking options, and energy efficiency make it a worthy investment for anyone serious about their culinary endeavors. Whether baking bread, roasting vegetables, or simmering sauces, the DC6 provides a powerful and reliable cooking platform that fulfills the dreams of every home chef.