Front Panel Menus - Additions

The Power Analyzer input uses the same front panel menu commands that are used to measure the Main

Output of the ac source. These are documented in the ac source User’s Guide. The following menu

commands have been added to let you access the Power Analyzer input, control the output frequencyÙ

modulation, and calibrate the Power Analyzer input. In most cases you will need to press the

Function key multiple times to access the menu item. Press the ￿

Entry key to access the parameter.

 

 

Phase

Ù

 

 

 

 

 

 

Select

 

 

Ù

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Freq

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shift

 

 

Cal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

φ1 115V 60 Hz φ2 120V 60 Hz

FM OFF

FM:FREQ 50

FM:DEV 10

FREQ:SRC VOLT

CAL:CURR: EXT

CAL:VOLT: EXT SHUNT

Displays the Main Output measurement when φ1 is selected Displays the Power Analyzer measurement when φ2 is selected

Enable or disable output frequency modulation (OFF or ON) Specifies the modulating frequency of the output

Specifies the peak deviation of the output frequency modulation

Specifies the frequency input source (VOLT or CURR)

Begin external current calibration

Begin external voltage calibration

Enter a value for the external shunt in ohms

NOTE: With no signal connected to the Power Analyzer input, the φ2 front panel display may return a very high frequency value. This is normal, since there is no external frequency for the measurement circuit to detect.

SCPI Programming Commands - Additions

The Power Analyzer input uses the same measurement commands that are used to measure the Main Output of the ac source. These are documented in the ac source User’s Guide. The following SCPI commands have been added to let you access the Power Analyzer input, control the output frequency modulation, and calibrate the Power Analyzer input. Additional measurement functions let you measure transfer time, peak voltage, and phase locked loop performance when evaluating devices such as uninterruptible power supplies.

CALibrate

MEASure FETCh

:CURRent

:VOLTage

:EXTernal

:RANKed? <percentile>

:VOLTage

:TVOLt? <level><occurrence>

:EXTernal

:ABSolute? <level><start_time><min_pulse_width>

:SHUNt

 

FM

SENSe

:STATe <bool>

:NSELect 1 2

:DEViation <value>

:FREQuency:SOURce VOLT CURR

:FREQuency <value>

 

4

Page 4
Image 4
Agilent Technologies 5964-8134 manual Front Panel Menus Additions, Scpi Programming Commands Additions

5964-8134 specifications

Agilent Technologies 5964-8134 is an advanced analytical instrument designed for versatile applications in laboratory settings. It serves as a crucial component for professionals working in fields such as forensic science, environmental testing, and pharmaceutical analysis.

One of the primary features of the 5964-8134 is its exceptional chromatographic performance. The device employs sophisticated separation techniques, utilizing a high-efficiency column that enhances the resolution of complex mixtures. This capability allows scientists to identify and quantify trace levels of compounds in samples with high precision.

Equipped with a state-of-the-art detector, the 5964-8134 offers a broad dynamic range to accommodate various analyte concentrations. This feature ensures that both minor and major components can be accurately measured, making it ideal for applications involving diverse sample matrices. The integrated software provides users with easy access to data analysis tools, enabling seamless interpretation of results.

The 5964-8134 is built on cutting-edge technology, including advanced mass spectrometry which enhances its sensitivity and specificity. This technology enables the detection of low-abundance compounds in complex samples, providing insights that would be difficult to obtain using traditional methods. Additionally, the instrument supports multiple ionization techniques, allowing users to tailor the analysis to specific requirements of their project.

Another characteristic of the Agilent 5964-8134 is its user-friendly interface. The equipment is designed with the operator in mind, featuring intuitive controls and a touchscreen display that promotes ease of use. This design minimizes the learning curve for new users, enabling efficient operation and streamlined workflow in busy laboratory environments.

Moreover, the 5964-8134 ensures robust performance with its advanced temperature control and reliable fluidic systems. These features contribute to improved reproducibility and stability during analyses, which are critical in achieving consistent results across experiments.

With its combination of high performance, cutting-edge technologies, and user-centric design, Agilent Technologies 5964-8134 stands out as a leading choice for professionals seeking reliable and accurate analytical solutions. As laboratories continue to demand innovative instruments that push the boundaries of research capabilities, the 5964-8134 proves to be an essential tool in scientific discovery and analysis.