Voltage: 3 V to 60 V (minimum dc operation from 0 to 2 V for 0 to 60 A)

Table 60502-1. Specification and Supplemental Characteristics

SPECIFICATIONS

DC Input Rating:

Current: 0 to 60 A

Voltage: 3 V to 60 V (minimum dc operation from 0 to 2 V for 0 to 60 A)

Power: 300 W at 40 °C (derated to 225 W at 55 °C)

A. OPERATING CHARACTERISTICS

B. DERATED CURRENT DETAIL

Constant Current Mode:

 

Ranges:

0 to 6 A; and 0 to 60 A

Accuracy:

(after 30 second wait): ± 0.1% ± 75 mA (both ranges)

Resolution:

1.6 mA (6 A range); 16 mA (60 A range)

Regulation:

10 mA (both ranges)

Temperature Coefficient:

100 ppm/°C ± 5 mA/°C (both ranges)

Constant Resistance Mode:

 

Ranges:

0.033 to 1 Ω; 1 Ω to 1 kΩ; and 10 Ω to 10 kΩ

Accuracy:

± 0.8% ± 8 m Ω with 6 A at input (1 Ω range);

 

± 0.3% ± 8 mS with 6 V at input (1 kΩ and 10 kΩ ranges)

Resolution:

0.27 mΩ (1 Ω range); 0.27 mS (1 kΩ range); 0.027 mS (10 kΩ range)

Regulation:

10 mV with remote sensing (1 Ω range); 10 mA (1 k and 10 kΩ ranges)

Temperature Coefficient:

800 ppm/°C ± 0.4 mΩ/°C (1 Ω range);

 

300ppm/°C ± 0.6 mS/°C (1 k and 10 kΩ ranges)

Constant Voltage Mode:

 

Range:

0 to 60 V

Accuracy:

± 0.1% ± 50 mV

Resolution:

16 mV

Regulation:

10 mV (remote sense); 40 mV (local sense)

Temperature Coefficient:

100 ppm/°C ± 5 mV/°C