Agilent Technologies 60502B manual 3% to 97% 0.25 Hz to 1 kHz 6% to 94% 1 kHz to 10 kHz

Models: 60502B

1 11
Download 11 pages 45.05 Kb
Page 5
Image 5

Table 60502-1 Specifications and Supplemental Characteristics (continued)

Transient Operation:

 

Continuous Mode

 

Frequency Range:

0.25 Hz to 10 kHz

Frequency Resolution:

4%

Frequency Accuracy:

3%

Duty Cycle Range:

3% to 97% (0.25 Hz to 1 kHz); 6% to 94% (1 kHz to 10 kHz)

Duty Cycle Resolution:

4%

Duty Cycle Accuracy:

6% of setting ± 2%

Pulsed Mode

 

Pulse Width:

50 μs ± 3% minimum; 4 s ± 3% maximum

Transient Current Level (0 to 6 A and 0 to 60 A ranges):

Resolution:

26 mA (6 A range); 260 mA (60 A range)

Accuracy:

± 0.1% ± 80 mA (6 A range); ± 0.1% ± 350 mA (60 A range)

Temperature Coefficient:

100 ppm/°C ± 7 mA/°C

Transient Resistance Level (0.033 to 1 Ω, 1 Ω to 1 kΩ, and 10 Ω to 10 kΩ ranges):

Resolution:

4.3 mΩ (1 Ω range); 4.3 mS (1 kΩ range); 0.4 mS (10 kΩ range)

Accuracy:

± 0.8% + 8 mΩ with > 6 A at input (1 Ω range)

 

± 0. 3% + 10 mS with 6 V at input (1 kΩ range)

 

± 0.3% + 7 mS with 6 V at input (10 kΩ range)

Transient Voltage Level (0 to 60 V):

 

Resolution:

260 mV

Accuracy:

± 0.1% ± 300 mV

Temperature Coefficient:

150 ppm/°C ± 5 mV/°C

Current Readback:

 

Resolution:

17 mA (via GPIB); 20 mA (front panel)

Accuracy:

(after 30 minute wait): ± 0.05% ± 65 mA

Temperature Coefficient:

50 ppm/ °C ± 5 mA/ °C

Voltage Readback:

 

Resolution:

17 mV (via GPIB); 20 mV (front panel)

Accuracy:

± 0.05% ± 45 mV

Temperature Coefficient:

50 ppm/°C ± 1.2 mV/°C

Maximum Readback Capability:

65 to 70 V (typical)

Power Readback:

 

Accuracy:

± 0.2% ± 4 W