Agilent Technologies 60502B manual Range

Models: 60502B

1 11
Download 11 pages 45.05 Kb
Page 7
Image 7

 

Table 60502-1 Specifications and Supplemental Characteristics (continued)

Current Slew Rate:*

 

 

 

Rate # 60 A Range Step

6 A Range Step

Transition Time

1

1 A/ms

0.1

A/s

8.0 ms

2

2.5 A/ms

0.25 A/s

3.2 ms

3

5 A/ms

0.5

A/s

1.6 ms

4

10 A/ms

1 A/ms

800 μs

5

25 A/ms

2.5

A/ms

320 μs

6

50 A/ms

5 A/ms

160 μs

7

0.1 A/μs

10 A/ms

80 μs

8

0.25 A/μs

25 A/ms

32 μs

9

0.5 A/μs

50 A/ms

16 μs

10

1 A/μs

0.1

A/μs

12 μs

11

2.5 A/μs

0.25 A/μs

12 μs

12

5 A/μs

0.5

A/μs

12 μs

 

*AC performance specified from 3 to 60 V.

Voltage Slew Rate:

 

 

Rate # Voltage Range Step

Transition Time*

1

1 V/ms

8.0 ms

2

2.5 V/ms

3.2 ms

3

5 V/ms

1.6 ms

4

10 V/ms

800 μs

5

25 V/ms

320 μs

6

50 V/ms

160 μs

7

0.1 V/μs

85

μs

8

0.25 V/μs

85

μS

9

0.5 V/μs

85

μS

*Transition time based on low capacitance current source.

Resistance Slew Rate (1 Ω range): Uses the value programmed for voltage slew rate.

Resistance Slew Rate (1 k and 10 kΩ ranges): Uses the value programmed for current slew rate.

Transient Current Overshoot (When programmed from 0A):

 

Range

Transient Current Level

Current Slew Rate

Overshoot*

60 A

6-60 A

All slew rates

0

 

3 A

1 A/μs to 5 A/μs

1%

 

3 A

1 A/μs to 0.5 A/μs

0

6 A

6 A

All slew rates

0

 

3 A

0.25 A/μs to 0.5 A/μs

1%

 

3 A

0.1 A/ms to 0.1 A/μs

0

*Overshoot may be higher during the first five seconds of programming if unit has been operating at full current. Overshoot values assume a total inductance of lμH, or less, in the load leads connected to the D.U.T.