Agilent Technologies 60502B manual kHz 3 db frequency

Models: 60502B

1 11
Download 11 pages 45.05 Kb
Page 6
Image 6

Table 60502-1 Specifications and Supplemental Characteristics (continued)

External Analog Programming 0 to 10 V (dc or ac):

Bandwidth:

10 kHz (3 db frequency)

Accuracy:

± 4.5% ± 75 mA (0 to 6 A range)

 

± 4.5% ± 250 mA (0 to 60 A range)

 

± 0.8% ± 200 mV (0 to 60 V range)

Temperature Coefficient:

100 ppm/°C ± 6 mA/°C (current ranges)

 

100 ppm/°C ± 1 mV/°C (voltage range)

External Current Monitor (0 to 10 V):

 

Accuracy:

± 0.4% ± 85 mA (referenced to analog common)

Temperature Coefficient:

50 ppm/°C ± 6 mA/°C

External Voltage Monitor (0 to 10 V):

 

Accuracy:

± 0.25% ± 40 mV (referenced to analog common)

Temperature Coefficient:

50 ppm/ °C ± 0.2 mV/ °C

Remote Sensing:

5 Vdc maximum between sense and input binding posts

Maximum Input Levels:

 

Current:

61.2 A (programmable to lower limits)

Voltage:

75 V

Minimum Operating Voltage:

2 V (derated to 0 V at 0 A)

PARD (20 Hz to 10 MHz noise):

 

Current:

4 mA rms/40 mA p-p

Voltage:

6 mV rms

DC Isolation Voltage:

± 240 Vdc between + or - input binding post and chassis ground

Digital Inputs:

 

Vlo:

0.9 V maximum at Ilo = -1 mA

Vhi

3.15 V minimum (pull-up resistor on input)

Digital Outputs:

 

Vlo:

0.72 V maximum at Ilo = 1 mA

Vhi:

4.4 V minimum at Ilo - 20 μA

SUPPLEMENTAL CHARACTERISTICS

 

Programmable Slew Rate (For any given input transition, the time required will be either the total slew time or a minimum transition time, whichever is longer. The minimum transition time increases when operating with input currents under 1 A. The following are typical values; ± 25% tolerance):

4