How Frames are Generated How the Frame Generator Works
Agilent 81250 ParBERT SONET/SDH Frame Generator, November 2002 17

G1 Path Status Byte

The G1 path status byte is affect ed by the following alarms:
L-AIS / MS-AIS
•HP-REI
L-RDI / MS-RDI
Depending on which alarm is select ed, the G1 path status byte is
affected as follows :
•No errors:
0000 0000
•AIS on:
xxxx 0111
•HP-REI:
0001 0000

All Other Path Overhead

All other path overhead bytes will contain
0000 0000
prior to
scrambling.
SONET Line Overhead and SDH MS
Overhead Details

Pointer Bytes

All H1 bytes will be set to “not n ew data” and contain offset zero
(
0110 0000
).
All H2 bytes will contain offset zero (
0000 0000
).
All H3 bytes are undefined when there are no pointer negative
just ific atio ns; ( poin ter incr emen t and decr emen t are not avail able ), H3
will be used to allow a fixed B2 value, see “Single B2 Error” on
page 18 below.

K2 Byte

The K2 byte is only set for the first frame.
It is affected by the following alarms:
L-AIS / MS-AIS
L-RDI / MS-RDI