10 MULTI-MODE OPERATIONS

10 MULTI-MODE OPERATIONS

10-1

12 / OCT / 01 14:30

During replay

10-3

VIDEO OUT

 

ENTRANCE

 

1

 

2

14 / OCT / 01 13:30

 

 

ENTRANCE

SET

MONITOR

PLAY

ROOM

BRIGHTNESS

DARK

BRIGHTNESS

REC

RELEASE

TALK

 

JA-2MECD

During replay; When a door station has called or camera has been activated, it is indicated by an “on-screen” mark, and its call- in image is viewed and saved automatically. (Replay mode is ended.) View visitor and communicate.

Notes:

Room call-in has no on-screen mark shown. The replay mode is terminated.

When initiating replay, auto-picture memory (for door call-in) is not effective for approx. 2 seconds.

NTSC

14 / OCT / 01 13:30

To send video signal to AV equipment

The image on the monitor is printable via composite VIDEO OUT terminal, connected to a Video printer, etc. (Select a model which handles NTSC signals).

10-2

[1]

SET

REPLAY

REC

[2]

ENTRANCE 1

 

2

PLAY

 

 

SET

 

ENTRANCE

 

 

MONITOR

 

 

ROOM

REC

BRIGHTNESS

 

DARK

BRIGHTNESS

 

 

RELEASE

 

TALK

JA-2MECD

SET

SET

SET

 

PLAY

SET

11 TECHNICAL PRECAUTIONS

Technical Precautions

Operating temperature: 0°C ~ 40°C (+32°F ~ +104°F).

Image may vary when Door release button is held down. This is not a malfunction.

Cleaning: Clean the units with a soft cloth dampened with neutral household cleanser. Do not use any abrasive cleaner or cloth.

Door station is weather-resistant. But do not spray high-pressure water on door station directly. Unit trouble could result.

In case of system malfunction, turn off the power switch of master station. If this doesn’t solve the problem, disconnect DC power and contact qualified technician.

12 SPECIFICATIONS

When PLAY & REC buttons are both lit

1.When the system has not been used for months or turned off for more than 30 minutes after power failure, etc., PLAY & REC buttons are lit. In this case, press SET button. Two buttons lights turn off. Set PICTURE MEMORY MODE again.

2.If SET button is still lit or flashing, turn it off by following these steps: Release SURVEILLANCE-SET mode (Page10). SET flashes 10-1 Press PLAY During replay SET lit 10-3 Press SET To send video signal to AV equipment SET

light turns off

Notes:

When changing PICTURE MEMORY MODE, all the pictures previously saved will be erased.

Specifications

 

• Power source:

DC 24V

• Consumption:

(MAX) 750mA (JA-2MECD)

 

(MAX) 680mA (JA-2MCD).

 

(MAX) 290mA(JA-2HCD).

• Calling:

Chime & image, Approx. 30 sec.

Communication: AUTO Handsfree voice activation MANUAL Press to talk, release to listen

Video-monitor:

4 inch direct view TFT color LCD

Scanning line:

525 lines

Door release contact:

 

AC 12V, 0.35A (dry closure contact L, L).

 

Run a separate cable for audio/video signal

 

and door release contact.

• Dimensions:

210H x 160W x 42D(mm).

 

8-1/4”H x 6-5/16”W x 1-5/8”D.

• Weight:

820g (1.81 lbs.) (aprox.) (JA-2MECD)

 

770g(1.70 lbs.) (approx.) (JA-2MCD)

 

730g (1.61 lbs.) (approx.) (JA-2HCD)