Aiphone Ja-2hcd, JA-2MECD, JA-2MCD operation manual Mounting, Wiring method, Cable, Wiring distance

Models: Ja-2hcd

1 12
Download 12 pages 23.6 Kb
Page 3
Image 3
Wiring method

2-2

 

 

 

 

 

 

JA-2MECD

 

 

 

 

JA-DAC

JA-2MCD

JA-2HCD

JA-2HCD

 

 

 

 

 

2

4

 

 

4

 

2

 

 

 

B1, B2

 

JA-DAC

B1, B2

B1, B2

 

B1, B2

 

 

 

 

 

 

JA-2SD

JA-2SD

 

 

 

JA-2HCD

JA-2HCD

 

JA-2MECD

4

 

 

 

JA-DAC

JA-2MCD

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

4

JA-2SD

JA-2SD

 

B1, B2

 

 

 

 

 

 

 

 

 

 

 

JA-2HCD

JA-2HCD

 

JA-2MECD

 

 

 

 

JA-DAC

JA-2MCD

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

4

 

 

 

4

 

JA-2SD

JA-2SD

 

B1, B2

 

 

 

 

 

 

8

 

 

 

 

 

 

Wiring method

Wire the inside stations in a station-to-station (daisy-chained) manner.

2-3

 

(x2)

JA-2MECD

JA-2HCD

JA-2MCD

 

A1

A1

B1

B1

B1

JA-DAC

A2

A2

B2

B2

B2

 

A1

+

+

 

JA-D

 

 

A1

A2

-

-

 

 

 

 

A2

 

 

 

 

120Cable120Wiring distance

Cable

1.Use 2-conductor, non-shielded cable. Vinyl-jacketed cable with PE(polyethylene) insulated wires is recommended.

2.Never use loose wires, shielded wire, twisted pairs, or coaxial cable.

3.When using existing cable with multiple wires, terminate both ends of each unused pair with a 120 ohm resistor.

2-4

 

 

 

D1

A

A'

D2

 

 

 

 

 

JA-DAC

 

 

 

JA-D

 

JA-DAC

JA-2MECD

 

E

 

 

M

JA-2MCD

 

 

C

IER-2

 

 

D

 

 

PS

 

 

 

PS-2420

 

 

 

PS-2410

 

 

 

S1

 

B

ADAP

 

 

JAW-AZ

 

 

 

JA-2HCD

JA-2SD

 

 

 

 

CAM

 

 

 

 

S2

 

 

 

JA-2HCD

JA-2SD

 

 

 

 

CAM : motion detect sensor or sensor / camera

Wiring distance

 

 

0.65mm

 

22AWG

 

1.0mm

18AWG

A

 

50m

 

165'

 

100m

330'

A'

 

50m

 

165'

 

100m

330'

B

 

50m

 

165'

 

100m

330'

C

 

5m

 

16'

 

10m

33'

D

 

50m

 

245'

 

100m

330'

E

 

50m

 

165'

 

100m

330'

3

 

MOUNTING

 

 

 

 

 

 

 

 

 

[3]

 

 

 

 

 

[1]

[2]

 

46mm

JA-2MECD

 

 

 

 

(1-13/16")

JA-2MCD

 

 

 

 

 

JA-2HCD

 

 

 

 

 

 

 

 

 

 

 

 

83.5mm

 

 

 

 

 

 

 

(3-5/16")

 

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9mm

 

 

 

 

 

 

 

(3/8")

 

 

 

 

 

 

 

3.

 

 

 

 

 

 

 

PS-2420

 

 

 

PS-2420DIN

 

PS-2420S

 

 

 

PS-2410DIN

 

PS-2420UL

[2]

[3]

 

[4]

 

 

 

 

 

 

 

 

 

 

83.5mm

 

 

 

 

 

 

 

(3-5/16")

 

 

 

Mounting

 

 

 

 

 

[1]Screw (x4)

[2]Mounting bracket

[3]Two-gang box

Provide a box DEEP enough to accommodate all cables incl. options. [4] DIN rail

1.Depress UNLOCK button (to unlock or to insert the wire securely).

2.Insert the cable into terminal.

3.When GANG BOX is not provided, the cable can be surface run from the top or bottom of the unit. Cut open the cable inlet hole to run wires to the back of the unit.

- 3 -

Page 3