Add-on Selectors for the NEM Lamp Memory System

0108

N-20AS, 20-callN-40AS, 40-calln- INSTRUCTIONS -

Add-on Selectors for the NEM Lamp Memory System

N-20AS, 20-call

N-40AS, 40-call

- INSTRUCTIONS -

The N-20AS and N-40AS add-on selectors are designed to function with the NEM Lamp Memory System, Type "C" or later. Multiple add-on selectors can be added to a master station along with a variety of sub stations to create a communication system tailored to a user's needs. All standard NEM system accessories can be used in conjunction with the add-on selectors. Each add-on selector requires a dedicated 24V DC power supply.

1

2

NAMES & FUNCTIONS:

 

 

 

1.

OFF button

 

 

 

2.

Selector button

 

 

 

3.

OFF LED

 

 

 

 

 

 

4.

Directory card

 

 

 

5.

Station selector LED

 

 

 

N-nAS TERMINAL DEFINITIONS:

 

 

 

+

 

Positive 24V DC

 

 

 

-

 

Negative

 

 

 

1~40

Station number

 

 

 

E

 

Common communication

 

 

 

V1-V4 Connects to NB-U for

 

 

 

A1-A4

Background Music

3 4 5

Individual Components for System:

NEM-nMaster station (10, 20, 30, 40-call sizes)

NEM-nAMaster station with handset (10, 20, 30, 40-call sizes)

NA-series Any sub station with NA, NB, or NE model number prefix

PS-2420UL 24V DC, 2A Power Supply

Other Accessory items listed in catalog or price list as compatible with the NEM series.

SPECIFICATIONS:

 

Power Source:

24V DC. Use PS-2420UL.

Communication Output: 500mW at 20 ohms

Communication:

Push-to-talk, release-to-listen (TALK button), or VOX handset at master (handset models only).

 

Hands free at sub station.

All call output:

6W in a system of up to 20 sub stations

 

12W in a system between 21 and 40 stations.

Calling:

Master to sub: By voice only after pretone.

 

Sub to master: Call button on sub activates tone and LED, remaining activated until answered.

Wiring:

2 conductors homerun to sub station, or loop multi-conductor cable with 1 common wire

 

plus 1 individual wire per sub station on the wire run.

 

Shielded cable is recommended. Use Aiphone #822202 (22AWG) or #821802 (18AWG) 2 cond.

 

Multiconductor: Aiphone #822210 (10 cond.), #822215 (15 cond.), #822220 (20 cond.)

Wiring Distance:

420' with 22AWG; 1,000' with 18AWG.