14.1Material Specifications 14.1.1 Reflectors

.024 Aluminum

(optional .024 Stainless Steel Type 304)

14.2Heater Specifications 14.2.1 Ignition

Honeywell® SmartValve® II combines gas valve and hot surface electronic ignition control. Fully auto- matic, four-try, 100% shut-off, prepurge, auto reset, LED indicator status.

14.3 Suspension Specifications

Hang heater with materials with a minimum working load of 75 lbs (33 kg). See Page 14, Figure 14.

14.4 Controls Specifications

Time switches, thermostats, etc. can be wired into the electrical supply. External controls supplied as an optional extra.

General Specifications for the heaters are as follows:

End View

Side View

 

Minimum Length "A"

 

 

Reflector

 

 

 

 

13.5"

 

 

 

 

(34 cm)

 

 

 

 

9.5"

 

 

 

 

(24 cm)

 

 

 

 

 

17.5"

Burner Tube

Turbulator

 

 

(Select Models)

 

(44 cm)

 

 

 

 

Heat Input Rate

Length “A”

Recommended

 

Minimum Mounting Height*

 

 

 

Model

(Btu/h) x (1000)

Minimum

Space

Spot

CTH2-40

40

10' (3m)

8'-10' (2.4 - 3m)

8' (2.3m)

CTH2-60

60

20' (6m)

10'-12' (3 - 3.6m)

9' (2.7m)'

CTH2-80

80

20' (6m)

12'-15' (3.6 - 4.5m)

11' (3.3m)

CTH2-100

100

30' (9m)

12'-15' (3.6 - 4.5m)

12' (3.7m)

CTH2-125

125

40' (12m)

15'-20' (4.5 - 6m)

15' (4.6m)

CTH2-150

150

50' (15m)

20'-25' (6 - 7.6m)

20' (6.1m)

CTH2-175

175

60' (15m)

25' (7.6m)

23' (7m)

*See Page 5, Section 3 for clearances to combustibles.

GAS PRESSURE AT MANIFOLD:

Natural Gas:

3.5" wc

LP Gas:

10.5" wc

PIPE CONNECTION:

1/2" NPT (for 40, 60, 80, 100, 125) 3/4" NPT (for 150 & 175)

DIMENSIONS:

Vent Connection Size: 4" (10 cm)

Outside Air Connection Size: 4" (10 cm)

Refer to figure above for dimensional information.

GAS INLET PRESSURE:

 

 

Natural Gas:

 

 

for 40,60,80,100,125,150

4.6" wc

Minimum

for 175

5.0" wc

Minimum

 

14.0" wc

Maximum

LP Gas:

11.0" wc

Minimum

 

14.0" wc

Maximum

ELECTRICAL RATING (ALL MODELS):

120 V - 60 Hz., 1.0 A (run) 5.0 A (Start)