SECTION 5: MAJOR COMPONENTS

CTH2-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

SECTION 5: MAJOR COMPONENTS

FIGURE 13: Major Component Descriptions

Burner with Tube Gasket

Reflector

Must be installed with the

(Aluminum or

flame observation

Stainless

window facing down.

Steel)

 

Alternate overlap as

 

shown on overview and

 

on Page 16, Figure 16.

 

Minimum overlap is 6" (16 cm).

Burner Tube

Tube

Supplied in 10'

Hot rolled or heat

(3 m) lengths. Burner

treated aluminized tube

tube is always the first tube

supplied in 10' (3 m) lengths.

after the burner.

 

Tube and Reflector Hanger

Coupling Assembly

with Lock

with Clamp Package

 

Position this hanger no more

 

than 4" (10 cm) away from the

 

burner.

Reflector End Cap

 

 

Punch out center

Tube and Reflector Hanger

section to

accommodate tube.

Suspend system from these

 

hangers.

 

 

Vent Adapter

Reflector Support Strap &

Wire Form

 

Turbulator

 

Turbulator must

 

be installed in the last

 

standard section of tube.

Flex Gas Line with

Turbulator is not required on the

Shut Off Cock

CTH2-125/150/175. For

 

installation see Page 20,

 

Section 6.4.