Roberts Gorden CTH2-100, CTH2-125, CTH2-80 Ladder Diagram, Electrical Connection to the Burner

Models: CTH2-40 CTH2-60 CTH2-175 CTH2-150 CTH2-100 CTH2-80 CTH2-125

1 68
Download 68 pages 17.18 Kb
Page 50
Image 50

CTH2-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

10.5 Ladder Diagram

L 2

L 1

 

TRANSFORMER

WHITE

BLACK

ORANGE

 

BLUE

 

 

VALVE

 

TO

 

 

 

 

WHITE

PRESSURE

THERMOSTAT

 

 

SWITCH

 

 

YELLOW

 

 

 

YELLOW

 

 

 

 

PURPLE

 

WHITE

 

HOT SURFACE IGNITER

 

 

 

 

 

WHITE

 

 

 

WHITE

 

 

BLACK

 

 

 

GREY

 

 

DOOR

MOTOR

FLAME

 

SENSOR

 

SWITCH

 

 

 

 

 

WHITE

 

 

 

 

BLACK

 

10.6 Electrical Connection to the Burner

 

 

 

Electrical Cord or

 

 

Flexible Conduit

Burner

 

BX or Romex Connector

 

 

Connect wires together

L1

Junction Box

with suitable approved

L2

wire connectors.

Ground

 

Green to Ground

Black

 

White to L2

White

 

Black to L1

Green

 

44

 

 

Page 50
Image 50
Roberts Gorden CTH2-100, CTH2-125, CTH2-80, CTH2-150, CTH2-175 Ladder Diagram, Electrical Connection to the Burner

CTH2-40 CTH2-60, CTH2-175, CTH2-150, CTH2-100, CTH2-80 specifications

Roberts Gorden is a reputable name in the field of heating and energy efficiency, and its CTH2 series of infrared radiant heaters—including the CTH2-150, CTH2-80, CTH2-125, CTH2-100, and CTH2-175—are a testament to innovation and quality. Designed for commercial and industrial spaces, these heaters provide effective and efficient heating solutions tailored to various needs.

The CTH2 series employs advanced infrared heating technology, which radiates warmth directly to objects and individuals in the space rather than heating the air. This method ensures rapid heat-up times and energy conservation, making the heaters ideal for workshops, warehouses, and other large areas where traditional heating systems may be inefficient.

One of the main features of the CTH2 series is its high thermal efficiency. The heaters convert a significant portion of the energy consumed into usable heat, resulting in lower operational costs and a reduced carbon footprint. The CTH2 models utilize durable components designed to withstand the rigors of industrial environments, ensuring longevity and reliable performance.

The CTH2-150, CTH2-80, CTH2-125, CTH2-100, and CTH2-175 models vary in output capacity and design, providing flexibility for different heating requirements. The maximum heat output ranges significantly among the models, with the CTH2-175 offering the highest thermal output, making it suitable for larger spaces or areas requiring immediate and intense heating. Conversely, the CTH2-80 is ideal for smaller areas or those that require less heat.

Installation versatility is another key characteristic of the CTH2 series. These heaters can be mounted from the ceiling or installed horizontally or vertically, accommodating different building layouts and operational needs. The heaters are also designed for easy maintenance, featuring accessible components to facilitate routine checks and repairs.

The CTH2 series incorporates safety features such as overheat protection and flame safeguard systems, ensuring safe operation even in busy industrial settings. Additionally, their sleek and modern design allows them to integrate seamlessly with existing infrastructure without detracting from the overall aesthetic of the space.

In conclusion, Roberts Gorden’s CTH2 series—including the CTH2-150, CTH2-80, CTH2-125, CTH2-100, and CTH2-175—represents a pinnacle of infrared heating technology. With their impressive efficiency, customizable output, versatile installation options, and robust safety features, these heaters are a reliable choice for any commercial or industrial heating requirement.