Roberts Gorden CTH2-40 CTH2-60 Gas Connection with Flexible Gas Hose, Correct Positions, End View

Models: CTH2-40 CTH2-60 CTH2-175 CTH2-150 CTH2-100 CTH2-80 CTH2-125

1 68
Download 68 pages 17.18 Kb
Page 47
Image 47
FIGURE 23: Gas Connection with Flexible Gas Hose

SECTION 9: GAS PIPING

FIGURE 23: Gas Connection with Flexible Gas Hose

CORRECT POSITIONS

 

 

 

CAUTION

 

 

 

Product Damage Hazard

Shut-Off Valve (included with gas hose) must

Hold gas nipple securely with pipe wrench

be parallel to burner gas inlet. The 3" (8 cm)

displacement shown is for the cold condition.

when attaching gas hose.

This displacement may reduce when the

Failure to follow these instructions can result

system is fired.

 

 

 

 

 

in product damage.

 

 

 

Vertical

 

 

 

(as shown left)

 

3" (8 cm)

 

12"

max. displacement

45°

 

Side View

(30 cm)

 

 

 

 

 

Alternate

 

 

 

positions

 

 

 

okay

 

 

 

Horizontal

Flexible Gas Hose

 

End View

36" (91 cm) length

Heater Movement

 

 

INCORRECT POSITIONS (WRONG INSTALLATION)

Heater Movement

Heater Movement

Heater Movement

 

Heater Movement

 

 

 

 

 

 

 

 

 

 

Description

Part Number

 

 

 

1/2" Flexible Stainless Steel Gas Hose (US Models)

91412200

 

 

 

 

 

 

 

 

3/4" Flexible Stainless Steel Gas Hose (US Models)

91412204

 

 

 

 

 

 

 

 

1/2" Rubber Type 1 Gas Hose (Canadian Models)

91412206

 

 

 

 

 

 

 

 

3/4" Rubber Type 1 Gas Hose (Canadian Models)

91412207

 

 

 

 

 

 

 

 

 

 

41

Page 47
Image 47
Roberts Gorden CTH2-40 CTH2-60 Gas Connection with Flexible Gas Hose, Correct Positions, Product Damage Hazard, Side View