VXI Technology, Inc.

Programmable Timing Delays

A delay can be programmed between relay closures to allow for settling times of other system resources. When used with triggers, a controlled synchronous switching system can easily be configured.

Safety Interrupt

This is a programmable fail-safe feature that allows all relays to open based upon the occurrence of a selected TTL backplane trigger. This allows signals to be removed from the unit under test if a system fail-safe occurs, such as inadvertent removal of a test adapter.

 

SM7100 SPECIFICATIONS

 

 

 

 

SM7000 SPECIFICATIONS

 

 

 

MAXIMUM POWER HANDLING (CW)

 

 

At 18 GHz

20 W, 100 W peak pulse

 

SWITCHING TIME

 

 

 

 

< 15 ms

 

 

RF IMPEDANCE

 

 

 

 

50 Ω

 

 

FREQUENCY (GHz)

dc – 3

3 – 18

18 – 20

Isolation (dB min)

90

80

60

Insertion Loss (dB max)

1.0

2.8

3.0

VSWR

1.2:1

1.6:1

2.0:1

SWITCH LIFE

1,000,000 cycles per switch

CONNECTORS

SMA

POWER REQUIREMENTS

+5 V @ 0.30 A -5.2 V @ 0.10 A -2 V @ 0.10 A

160 mA current draw per relay closure at +24 V

COOLING REQUIREMENTS

2.22 L/s

10

SM7100 Introduction

Page 10
Image 10
VXI Microwave Matrix user manual SM7100 Specifications, Vswr, Sma