VXI Technology, Inc.
Programmable Timing Delays
A delay can be programmed between relay closures to allow for settling times of other system resources. When used with triggers, a controlled synchronous switching system can easily be configured.
Safety Interrupt
This is a programmable
| SM7100 SPECIFICATIONS | ||
|
|
|
|
SM7000 SPECIFICATIONS |
|
|
|
MAXIMUM POWER HANDLING (CW) |
|
| |
At 18 GHz | 20 W, 100 W peak pulse |
| |
SWITCHING TIME |
|
|
|
| < 15 ms |
|
|
RF IMPEDANCE |
|
|
|
| 50 Ω |
|
|
FREQUENCY (GHz) | dc – 3 | 3 – 18 | 18 – 20 |
Isolation (dB min) | 90 | 80 | 60 |
Insertion Loss (dB max) | 1.0 | 2.8 | 3.0 |
VSWR | 1.2:1 | 1.6:1 | 2.0:1 |
SWITCH LIFE
1,000,000 cycles per switch
CONNECTORS
SMA
POWER REQUIREMENTS
+5 V @ 0.30 A
160 mA current draw per relay closure at +24 V
COOLING REQUIREMENTS
2.22 L/s
10 | SM7100 Introduction |