b-5

OPERATION

b-5

 

 

 

20. CIRCUIT bREAKERS

These circuit breakers provide separate overload current protection for each 120V circuit at the 240V single phase receptacle, each 120V single phase receptacle, the 240V three phase recepta- cle, the 120VAC in the 14-Pin connector, the 42VAC in the 14-Pin connector and battery circuit overload protection.

21. 120VAC SINGLE PHASE RECEPTACLES

These two 120VAC (5-20R) receptacles with ground fault circuit interruption protection provide 120VAC single phase for auxiliary power. Each receptacle has a 20 amp total rating. They are designed to protect the user from the hazards of ground faults. When the GFCI has tripped there will be no voltage available from the receptacle. Refer to the AUXILIARY POWER RECEPTA- CLES section in the installation chapter for further information about these receptacles. Also refer to the AUXILIARY POWER OPERATION section later in this chapter.

22. GROUND STUD

Provides a connection point for connecting the machine case to earth ground. Refer to “MACHINE GROUNDING” in the Installation chap- ter for proper machine grounding information.

23. 240VAC THREE PHASE RECEPTACLE

This is a 240VAC (15-50R) receptacle that pro- vides 240VAC three phase auxiliary power. This receptacle has a 50 amp rating.

AIR COMPRESSOR CONTROLS (24 THRU 27)

24. COMPRESSOR ON/OFF SWITCH

Turns compressor on and off activating or deacti- vating the electromagnetic compressor clutch.

25. COMPRESSOR PROTECTION LIGHT

The yellow compressor protection light remains off with proper compressor oil temperatures. If the lights turn on, the compressor protection system will deactivate the compressor clutch and put the system in standby mode until the temperature reaches allowable limits. Check for proper com- pressor oil level.

26. COMPRESSOR HOUR METER

The compressor hour meter displays the total time that the compressor has been running (com- pressor switch must be on).

27. AIR DISCHARGE VALVE

Controls flow of compressed air. A 3/4” NPT (National Pipe Thread) fitting is provided.

bATTERY JUMP START TERMINAL (28-31)

28.POSITIVE bATTERY JUMP START TERMINAL.

29.NEGATIVE bATTERY JUMP START TERMINAL.

12V battery jump start feature is standard. Covered output studs for convenient access, and protection against accidental impact. can be used to jump-start a utility truck with up to 800 cold cranking amps. Can also be used to jump-start the AIR VANTAGE® 500 CUMMINS.

30. bATTERY DISCONNECT SWITCH

Battery disconnect switch provides lockout/tagout capability. Switch is conveniently located on the front bottom of the machine.

31. AIR CLEANER AND SERVICE INDICATOR

Air cleaner service indicator provides a Go/No-Go visual indication of useful filter service life. Also located inside the engine compartment. (SEE FIG- URE B.2)

FIGURE b.2

31

AIR VANTAGE® 500 CUMMINS

Page 24
Image 24
Air Vent Inc IM10065 manual AIR Compressor Controls 24 Thru

IM10065 specifications

Air Vent Inc's IM10065 is a notable product in the field of ventilation systems, designed to enhance airflow and maintain optimal indoor air quality. As part of Air Vent's commitment to innovative and effective ventilation solutions, the IM10065 model stands out due to its advanced features and technologies.

One of the primary characteristics of the IM10065 is its efficient design, tailored for use in various residential applications. This product is particularly effective in preventing moisture accumulation within attics, thereby mitigating potential mold growth and ensuring a healthier living environment. By promoting proper ventilation, it helps to regulate temperature and humidity, making it an essential component for any modern home.

The IM10065 employs a reliable polypropylene construction that ensures durability and longevity. This material is not only lightweight but also resistant to corrosion, rust, and weathering, making it suitable for a range of outdoor climates. The robust construction minimizes the risk of damage over time, ensuring that the ventilation system functions optimally throughout its lifespan.

An important aspect of the IM10065 is its installation flexibility. The device can be easily integrated into various roofing types, which simplifies the setup process for contractors and homeowners alike. Moreover, with its low profile design, the IM10065 blends seamlessly into the roofline, preserving the aesthetic appeal of residential properties.

Furthermore, the IM10065 features a unique baffle system that enhances airflow while reducing the chances of backdrafts or wind-driven rain entering the attic space. This innovative feature is pivotal in maintaining consistent airflow, which contributes to the overall energy efficiency of the home.

The IM10065 also includes mesh screening that effectively prevents insects and debris from entering the ventilation system. This protective measure ensures that the internal components remain clean and functional, thereby extending the lifespan of the ventilation system.

In summary, Air Vent Inc's IM10065 is a well-engineered product characterized by its durable materials, flexible installation options, and innovative design features. These attributes make it an excellent choice for homeowners seeking reliable ventilation solutions that promote healthier indoor environments while also contributing to energy efficiency and longevity. With its combination of quality construction and advanced technology, the IM10065 exemplifies the high standards set by Air Vent Inc in the ventilation industry.