Air Vent Inc IM10065 manual Connection of Lincoln ELEC- Tric Wire Feeders, Across The-Arc Model

Models: IM10065

1 54
Download 54 pages 48.72 Kb
Page 18
Image 18

A-8

INSTALLATION

A-8

 

 

 

CONNECTION OF LINCOLN ELEC- TRIC WIRE FEEDERS

WARNING

Shut off welder before making any electrical con- nections.

------------------------------------------------------------------------

Connection of LN-7, LN-8 OR LN-742 to the AIR VANTAGE® 500 CUMMINS

1.Shut the welder off.

2.Connect the LN-7, LN-8 OR LN-742 per instruc- tions on the appropriate connection diagram in Section F.

3.Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode being used.

4.Set the "MODE" switch to the "CV WIRE " posi- tion.

5.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

6.Set the "WELD TERMINALS" switch to the "REMOTELY CONTROLLED" position.

7.Set the "IDLE" switch to the "HIGH" position.

Connection of LN-15 to the AIR VANTAGE® 500 CUMMINS

These connections instructions apply to both the LN-

15Across-The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

1.Shut the welder off.

2.For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For elec- trode Negative, connect the electrode cable to the "-" terminal of the welder and work cable to the "+" terminal of the welder.

3.Across The-Arc Model:

Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON".

When the gun trigger is closed, the current sens- ing circuit will cause the AIR VANTAGE® 500 CUMMINS engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approxi- mately 12 seconds unless welding is resumed.

4.Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the "WELD TERMINALS" switch to

"REMOTELY CONTROLLED"

Set the MODE switch to the "CV-WIRE " position.

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polar- ity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "AUTO" position.

When the gun trigger is closed, the current sens- ing circuit will cause the AIR VANTAGE® 500 CUMMINS engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approxi- mately 12 seconds unless welding is resumed.

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

AIR VANTAGE® 500 CUMMINS

Page 18
Image 18
Air Vent Inc IM10065 Connection of Lincoln ELEC- Tric Wire Feeders, Connection of LN-15 to the AIR Vantage 500 Cummins

IM10065 specifications

Air Vent Inc's IM10065 is a notable product in the field of ventilation systems, designed to enhance airflow and maintain optimal indoor air quality. As part of Air Vent's commitment to innovative and effective ventilation solutions, the IM10065 model stands out due to its advanced features and technologies.

One of the primary characteristics of the IM10065 is its efficient design, tailored for use in various residential applications. This product is particularly effective in preventing moisture accumulation within attics, thereby mitigating potential mold growth and ensuring a healthier living environment. By promoting proper ventilation, it helps to regulate temperature and humidity, making it an essential component for any modern home.

The IM10065 employs a reliable polypropylene construction that ensures durability and longevity. This material is not only lightweight but also resistant to corrosion, rust, and weathering, making it suitable for a range of outdoor climates. The robust construction minimizes the risk of damage over time, ensuring that the ventilation system functions optimally throughout its lifespan.

An important aspect of the IM10065 is its installation flexibility. The device can be easily integrated into various roofing types, which simplifies the setup process for contractors and homeowners alike. Moreover, with its low profile design, the IM10065 blends seamlessly into the roofline, preserving the aesthetic appeal of residential properties.

Furthermore, the IM10065 features a unique baffle system that enhances airflow while reducing the chances of backdrafts or wind-driven rain entering the attic space. This innovative feature is pivotal in maintaining consistent airflow, which contributes to the overall energy efficiency of the home.

The IM10065 also includes mesh screening that effectively prevents insects and debris from entering the ventilation system. This protective measure ensures that the internal components remain clean and functional, thereby extending the lifespan of the ventilation system.

In summary, Air Vent Inc's IM10065 is a well-engineered product characterized by its durable materials, flexible installation options, and innovative design features. These attributes make it an excellent choice for homeowners seeking reliable ventilation solutions that promote healthier indoor environments while also contributing to energy efficiency and longevity. With its combination of quality construction and advanced technology, the IM10065 exemplifies the high standards set by Air Vent Inc in the ventilation industry.