MAINTENANCE

D-1

 

 

 

SAFETY PRECAUTIONS

WARNING

Have qualified personnel do all maintenance and troubleshooting work.

Turn the engine off before working inside the machine or servicing the engine.

Remove guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete. If guards are missing from the machine, obtain replacements from a Lincoln Distributor. (See Operating Manual Parts List.)

Read the Safety Precautions in the front of this manual and in the Engine Owner’s Manual before working on this machine.

Keep all equipment safety guards, covers, and devices in position and in good repair. Keep hands, hair, clothing, and tools away from the gears, fans, and all other moving parts when starting, operating, or repairing the equipment.

------------------------------------------------------------------------

ROUTINE AND PERIODIC MAINTENANCE

DAILY

Check the Engine and Compressor oil levels .

Refill the fuel tank to minimize moisture condensa- tion in the tank.

Open the water drain valve located on the bottom of the water separator element 1 or 2 turns and allow to drain into a container suitable for diesel fuel for 2 to 3 seconds. Repeat the above drainage procedure until diesel fuel is detected in the container.

Check coolant level.

WARNING

• Only VMAC certified and approved synthetic oil MUST be used. Shut down the Welder/Compressor for 3 minutes, open the pressure supply valve to ensure the system is depressurized prior to removing the compres- sor oil level dipstick.

------------------------------------------------------------------------

WEEKLY

Blow out the machine with low pressure air periodical- ly. In particularly dirty locations, this may be required once a week.

COMPRESSOR MAINTENANCE

Refer to the “Routine Maintenance” section of the compressor owner’s manual for the recommended maintenance schedule of the following:

a. Compressor oil and filter. b. Compressor air filter.

c. Compressor coalescing filter.

VMAC

(VEHICLE MOUNTED AIR COMPRESSORS)

WWW.VMAC.CA

1333 Kipp Road

Nanamino

British Columbia

Canada, V9X1R3

Telephone: (250) 740-3200

Facsimile: (250) 740-3201

Toll Free: 800-738-8622

ENGINE MAINTENANCE

Refer to the “Periodic Checks” section of the Engine Operator’s Manual for the recommended maintenance schedule of the following:

a)Engine Oil and Filter

b)Air Cleaner

c)Fuel Filter - and Delivery System

d)Alternator Belt

e)Battery

f ) Cooling System

Refer to Table D.1 at the end of this section for vari- ous engine maintenance components.

AIR FILTER

CAUTION

Excessive air filter restriction will result in reduced engine life.

WARNING

Never use gasoline or low flash point solvents for cleaning the air cleaner element. A fire or explosion could result.

CAUTION

Never run the engine without the air cleaner. Rapid engine wear will result from contaminants, such as dust and dirt being drawn into the engine.

------------------------------------------------------------------------

The diesel engine is equipped with a dry type air filter. Never apply oil to it. Service the air cleaner as follows:

Replace the element as indicated by the service indi- cator. (See Service Instructions and Installation Tips for Engine Air Filter.)

AIR VANTAGE® 500 CUMMINS

Page 30
Image 30
Air Vent Inc IM10065 manual Compressor Maintenance

IM10065 specifications

Air Vent Inc's IM10065 is a notable product in the field of ventilation systems, designed to enhance airflow and maintain optimal indoor air quality. As part of Air Vent's commitment to innovative and effective ventilation solutions, the IM10065 model stands out due to its advanced features and technologies.

One of the primary characteristics of the IM10065 is its efficient design, tailored for use in various residential applications. This product is particularly effective in preventing moisture accumulation within attics, thereby mitigating potential mold growth and ensuring a healthier living environment. By promoting proper ventilation, it helps to regulate temperature and humidity, making it an essential component for any modern home.

The IM10065 employs a reliable polypropylene construction that ensures durability and longevity. This material is not only lightweight but also resistant to corrosion, rust, and weathering, making it suitable for a range of outdoor climates. The robust construction minimizes the risk of damage over time, ensuring that the ventilation system functions optimally throughout its lifespan.

An important aspect of the IM10065 is its installation flexibility. The device can be easily integrated into various roofing types, which simplifies the setup process for contractors and homeowners alike. Moreover, with its low profile design, the IM10065 blends seamlessly into the roofline, preserving the aesthetic appeal of residential properties.

Furthermore, the IM10065 features a unique baffle system that enhances airflow while reducing the chances of backdrafts or wind-driven rain entering the attic space. This innovative feature is pivotal in maintaining consistent airflow, which contributes to the overall energy efficiency of the home.

The IM10065 also includes mesh screening that effectively prevents insects and debris from entering the ventilation system. This protective measure ensures that the internal components remain clean and functional, thereby extending the lifespan of the ventilation system.

In summary, Air Vent Inc's IM10065 is a well-engineered product characterized by its durable materials, flexible installation options, and innovative design features. These attributes make it an excellent choice for homeowners seeking reliable ventilation solutions that promote healthier indoor environments while also contributing to energy efficiency and longevity. With its combination of quality construction and advanced technology, the IM10065 exemplifies the high standards set by Air Vent Inc in the ventilation industry.