CONTROL PADS ON THE DEHUMIDIFIER

Power on

Continuous

Bucket full

High fan

Normal fan

indicator light

operation on

indicator light

indicator

 

indicator light

5

light

indicator light

 

 

 

Power

 

 

 

Normal

 

Continuous

 

Turbo

 

 

C

Full

 

 

 

 

Humidity%

 

 

1

 

 

 

4

2

 

 

 

 

 

3

 

Fig.1

 

 

 

 

Control pads

1POWER Pad

Press to turn the dehumidifier on and off.

2Continue Pad

Select for the dehumidifier to operate continuously for maximum dehumidification until the bucket is full. The Humdity set control pads cannot be used when Continuous operation is on.

3Humidity Set Control Pads

The humidity level can be set within a range of 35%RH(Relative Humidity) to 80%RH(Relative Humidity) in 5% increments.

For drier air, press the 1POWER Pad pad and set to a lower percent value(%).

For damper air, press the 2Continue Pad pad and set a higher percent value(%).

4Fan speed Pads

Control the fan speed. Press to select either High or Normal fan speed. Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Normal.

5Display

Shows the set % humidity level while setting, then shows the actual(+5% accuracy) room % humidity level.

Error Codes:

E1- Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for service.

E2- Temperature sensor error-- Unplug the unit and plug it back in. If error repeats, call for service.

P1- Unit is defrosting-- Allow the unit time to automatically defrost. The error will clear after the unit self defrosts.

P2- Bucket is full-- Empty the bucket and replace in the right position.

Other features

Bucket Full Light

Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper position.

Auto Shut Off

The water level control switch shuts off the dehumidifier when the bucket is full, or when the bucket is removed or not replaced in the proper position. When the setting humidity

is reached, the unit will be shut off automatically.

Auto Defrost

When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.

Power Outage

In the case of a power outage or interruption, the unit will automatically re-start, in the settings last used, after the power is restored.