Operating Instructions
Diagnostic Microprocessor Control
General Operation
The Diagnostic Microprocessor Control (DMP) is designed to manage the drying and cooling cycles of the tumbler. The controller is also programmed from the factory with five different default programs as described below. The operator has the flexibility to select the time for the drying and the cool down cycles and the drying temperature. The operator may also select either reversing or nonreversing basket action only if the tumbler is equipped for reversing. The operator may also reprogram the default programs. See Programming.
Default Programs
Programs | Dry Time (Min.) | Cool Time (Min.) | Temp. Set Point | Reversing | |
|
|
|
|
| |
1 – Towels | 40 | 5 | 185º/195ºF | No | |
(85º/91ºC) | |||||
|
|
|
| ||
|
|
|
|
| |
2 – Sheets | 30 | 5 | 165ºF (74ºC) | Yes | |
|
|
|
|
| |
3 – | 30 | 5 | 150ºF (66ºC) | No | |
|
|
|
|
| |
4 – | 25 | 5 | 135ºF (57ºC) | Yes | |
|
|
|
|
| |
5 – Extra Dry | 5 | 2 | 150ºF (66ºC) | No | |
|
|
|
|
|
NOTE: If an altered program is determined to be corrupted, the default program settings will be used.
Table 1
Features
●Drying time: 0-60 minutes
●Cooling time: 2-60 minutes
●LED display of cycle time, set temperature, and actual temperature
●Thermistor controlled temperature
●Safety tumble cycle
●Buzzer for end of cycle, audible alarm
●Reversing/Nonreversing selection
●Five user programmable programs
●RPM display – when equipped with rotational sensor only
●Monitors the lint door switch operation
●Monitors the thermistor for operation
The minimum drying time is 0 minutes, and the minimum cooling time is 2 minutes. The maximum drying or cooling time is 60 minutes. The drying temperature may be set from 100ºF (38ºC) to 185º/ 195ºF (85º/91ºC). The drying time, cooling time, or temperature may be modified during an operating cycle.
If it is necessary to reset the drying and cooling times for the current cycle, press STOP once to stop the tumbler. Press STOP again to cancel the cycle.
If it is necessary to change programs during a current cycle, press STOP once to stop the tumbler and press STOP again to cancel the current cycle.
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70400201 |