Operating Instructions

DMP OPL Models

DO Control Suffix

Description of the OPL Control Panel

Refer to Figure 6.

6

5

8

1

2

3

4

5

DRYING

4 COOLING TEMPERATURE

REV START STOP

(CANCEL)

7

8

9

10 11

12

3

1

2

TMB1956N

TMB1956N

1START. Starts or resumes the current program or cycle.

2STOP. Temporarily halts the current cycle or cancels the current program.

3Reversing/Nonreversing (REV). Changes the selection between reversing and nonreversing cylinder action.

4Reversing LED. Illuminated when set for reversing.

5Up/Down Arrows. Increases or decreases the value in the display. In conjunction with the DISPLAY button, these buttons are used to adjust the drying time, cooling time, temperature, clockwise time, dwell time, counter-clockwise time, and minutes per coin (Coin only).

6Display. Displays the drying time, cooling time, drying temperature and diagnostic codes.

7Program Select. This button toggles through the five user programmable programs. Holding this button will save a program, as indicated in Programming.

8User Program LEDs. Illumination shows which user program is currently being displayed.

9Display Select. Toggles the display between the drying time, cooling time, and temperature settings. Pressing the Display button for 3 seconds allows the user to display the drying cycle temperature.

10DRYING LED. Illuminated when in the drying cycle.

11COOLING LED. Illuminated when in the cooling cycle, or when the display is currently showing the time for the cooling cycle.

12TEMPERATURE LED. Illuminated when the display is showing the temperature setting.

Figure 6

70400201

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

17