Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

Disconnect electric power to the tumbler before servicing.

Close gas shut-off valve to gas tumbler before servicing.

Close steam valve to steam tumbler before servicing.

Never start the tumbler with any guards/panels removed.

Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

W002

Quarterly Maintenance

Use a vacuum to clean air vents on drive motors.

Use a vacuum to clean lint from rear limit thermostat cover.

Refer to Service Manual on how to check and clean steam coils.

Check flow of combustion and ventilation air.

Check belt tension and condition.

Replace worn or cracked belts.

Bi-Annually Maintenance

Check mounting hardware for any loose nuts, bolts or screws.

Check gas connections for leakage.

Check for loose electrical connections.

Check steam connections for looseness and leakage.

Remove all front panels and vacuum, including coin drop mechanisms.

Check cylinder and front panel seals.

Inspect cabinet and inner panels for any damage, replace or repair as needed.

Clean burner tubes of any lint buildup.

70400201

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

25