Operating Instructions
In Door Open Mode, the control turns off the heater and motor when the door is opened during a run cycle. The timer will continue to count down time and the IN USE LED is lit.
End of Cycle ModeIn End of Cycle Mode, a cycle is complete and the IN USE LED is off. The control remains in this mode until the door is opened or additional vend has been satisfied.
TopoffsAny time the control receives a coin drop pulse during a cycle it will add the programmed dry time to the time currently remaining in the cycle. The maximum cycle time is 99 minutes, the control will not add time beyond 99 minutes. The cool down time will not change.
If the control receives a coin drop pulse during cool down the IN USE LED will flash briefly to indicate the coin input, the machine will exit cool down and it will start heating. The cycle time will be equal to the programmed dry time
Temperature Selector SwitchFor five minutes after the control is powered up, there is a diagnostic feature that allows the temperature selector switches to be tested.
When the temperature selector is changed, the new setting is displayed by flashing the IN USE LED as follows:
High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash
Error Codes
To Program a Short Test Cycle:
1.Unplug machine power cord.
2.Write down machine control dip switch settings, then set them all to the off position. Refer to Figure 5.
3.Plug machine in and start a cycle.
NOTE: With all control dip switches off, the total cycle time will be 1 minute long.
4.Once all testing is complete, unplug machine and
5.Plug machine in.
O 1 2 3 4 5 6 7 8
N
12345678
TMB2216N
Figure 5
WARNING
To reduce the risk of electric shock, fire, explosion, serious injury or death:
•Disconnect electric power to the tumbler before servicing.
•Close gas
•Close steam valve to steam tumbler before servicing.
•Never start the tumbler with any guards/panels removed.
•Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
|
| W002 |
|
|
|
|
|
|
Display | Definition | Corrective Action |
|
|
|
AF (flashing) | Airflow switch opened/closed 5 or | ● Check airflow switch. Replace if inoperative. |
more times in a running cycle. |
| |
|
| |
|
|
|
12 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 70400001 |