Electrical Requirements

For 200 Pound Tumble Dryer Models

Serial Plate Rating

Terminal Block

Rated

Breaker

Recommended Wire

Connections Required

Current*

Rating

Size

 

 

 

 

 

 

200-208V/60Hz/3ph

L1, L2, L3 and ground

14

20A - 3 pole

12 AWG (3.31 mm2)

240V/60Hz/3ph

L1, L2, L3 and ground

14

20A - 3 pole

12 AWG (3.31 mm2)

380V/50 or 60Hz/3ph

L1, L2, L3 and ground

8

15A - 3 pole

14 AWG (2.08 mm2)

400-415V/50Hz/3ph

L1, L2, L3 and ground

8

15A - 3 pole

14 AWG (2.08 mm2)

440V/60Hz/3ph

L1, L2, L3 and ground

7

15A - 3 pole

14 AWG (2.08 mm2)

460-480V/60Hz/3ph

L1, L2, L3 and ground

7

15A - 3 pole

14 AWG (2.08 mm2)

*Current ratings vary slightly depending on model; refer to serial plate.